3–Installation

Installing Firmware

3-14

59265-02  B

Installing Firmware

The switch comes with current firmware installed. You can upgrade firmware as 
new firmware becomes available using the CLI, QuickTools, or Enterprise Fabric 
Suite. This guide describes how to install firmware using QuickTools and the CLI. 
For information about installing firmware using Enterprise Fabric Suite, refer to the 

QLogic 5800V Series Enterprise Fabric Suite User’s Guide

.

Using QuickTools to Install Firmware

Using the CLI to Install Firmware

You can load and activate firmware upgrades on an operating switch without 
disrupting data traffic or re-initializing attached devices. If you attempt to perform a 
non-disruptive activation without satisfying the following conditions, the activation 
will fail:

The current firmware and the new firmware must support a non-disruptive 
activation. For information about compatible firmware versions, refer to the

 

Firmware Release Notes

.

No changes are being made to switches in the fabric including powering up, 
powering down, disconnecting or connecting ISLs, changing switch 
configurations, or installing firmware.

No port in the fabric is in the diagnostic state.

No Zoning Edit sessions are open in the fabric.

No changes are being made to attached devices including powering up, 
powering down, disconnecting, connecting, or adapter configuration.

Install firmware on one switch at a time in the fabric. If you are installing firmware 
on more than one switch, wait 120 seconds after the activation is complete before 
installing firmware on the next switch.

Ports that are stable when the non-disruptive activation begins, and then change 
states, will be reset. When the non-disruptive activation is complete, Enterprise 
Fabric Suite and QuickTools sessions reconnect automatically. However, Telnet 
sessions must be restarted manually.

NOTE:

If a non-disruptive activation fails, you will usually be prompted to try again 
later. Otherwise, the switch will perform a disruptive activation.

Summary of Contents for SANbox 5800V Series

Page 1: ...59265 02 B Installation Guide Stackable Fibre Channel Switch 5800V Series Firmware Version 8 0...

Page 2: ...ification QLogic Corporation assumes no responsibility for any errors that may appear in this document This switch is covered by one or more of the following patents 6697359 other patents pending Docu...

Page 3: ...s de conformit aux normes du minist re des Communications du Canada xii CE Statement xiii VCCI Class A Statement xiii Laser Safety Information xiv Electrostatic Discharge Sensitivity ESDS Precautions...

Page 4: ...02V 1 9 Switch Management 1 10 QuickTools Web Applet 1 10 Enterprise Fabric Suite 1 11 Command Line Interface 1 11 Application Programming Interface 1 11 Simple Network Management Protocol 1 12 Storag...

Page 5: ...Requirements 3 2 Environmental Conditions 3 2 Installing a Switch 3 3 Mount the Switch 3 4 Install the Transceivers 3 5 Configure the Workstation 3 7 Configuring the Workstation IP Address for Ethern...

Page 6: ...he Maintenance Menu Option 0 4 14 Unpacking a Firmware Image File in Maintenance Mode Option 1 4 14 Resetting the Network Configuration in Maintenance Mode Option 2 4 15 Resetting User Accounts in Mai...

Page 7: ...th a Loop Topology 2 11 2 7 Mesh Topology 2 12 2 8 Multistage Topology 2 13 2 9 Security Example Switches and Adapters 2 22 2 10 Security Example RADIUS Server 2 25 2 11 Security Example Management Se...

Page 8: ...Page 1 1 Fibre Channel Port Types 1 6 1 2 Serial Port Pin Identification 1 8 2 1 Zoning Database Limits 2 2 2 2 Port Transmission Distances 2 3 2 3 Extended Credit Distances and Cable Lengths 2 4 2 4...

Page 9: ...ntrols and connections Section 2 describes the factors to consider when planning a fabric Section 3 explains how to install and configure the switch Section 4 describes the diagnostic methods and trou...

Page 10: ...itrated Loop FC AL 2 Rev 6 8 Fibre Channel 10 bit Interface Rev 2 3 Definitions of Managed Objects for the Fabric Element in Fibre Channel Standard draft ietf ipfc fabric element mib 04 txt The Fibre...

Page 11: ...erletzungen zur Folge hat 3 4 3 9 Ein Vorsichtshinweis weist auf das Vorhandensein einer Gefahr hin die m glicherweise Ger tesch den zur Folge hat 3 5 3 5 4 16 5 2 Notes informatives relatives la s cu...

Page 12: ...rized changes or modifications could void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions This dev...

Page 13: ...lectromagnetic Field Immunity Test EN 61000 4 4 Electrical Fast Transient Burst Immunity Test EN 61000 4 5 Surge Immunity Test EN 61000 4 6 Immunity To Conducted Disturbances Induced By Radio Frequenc...

Page 14: ...s Because it is impractical to label the transceivers the following label is provided in this manual The following warning applies to XPAK optical transceivers Electrostatic Discharge Sensitivity ESDS...

Page 15: ...nt Interfaces aux media d interconnexion appel s SFP transceivers Interfaces aux media d interconnexion appel s XPAK transceivers Zug ngliche Teile Nur die folgenden Teile im QLogic 5800V Series Fibre...

Page 16: ...ware to make sure the software is free for all its users This General Public License applies to most of the Free Software Foundation s software and to any other program whose authors commit to using i...

Page 17: ...ted under the terms of this General Public License The Program below refers to any such program or work and a work based on the Program means either the Program or any derivative work under copyright...

Page 18: ...quired to print an announcement These requirements apply to the modified work as a whole If identifiable sections of that work are not derived from the Program and can be reasonably considered indepen...

Page 19: ...urce or binary form with the major components compiler kernel and so on of the operating system on which the executable runs unless that component itself accompanies the executable If distribution of...

Page 20: ...ance of the section is intended to apply and the section as a whole is intended to apply in other circumstances It is not the purpose of this section to induce you to infringe any patents or other pro...

Page 21: ...WISE STATED IN WRITING THE COPYRIGHT HOLDERS AND OR OTHER PARTIES PROVIDE THE PROGRAM AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES...

Page 22: ...more details You should have received a copy of the GNU General Public License along with this program if not write to the Free Software Foundation Inc 59 Temple Place Suite 330 Boston MA 02111 1307...

Page 23: ...ge to any person obtaining a copy of this software and associated documentation files the Software to deal in the Software without restriction including without limitation the rights to use copy modif...

Page 24: ...the Support tab at the top and then click the Training and Certification on the left The QLogic Global Training Portal offers online courses certification exams and scheduling of in person training Te...

Page 25: ...e collection of QLogic product information that you can search for specific solutions We are constantly adding to the collection of information in our knowledge base to provide answers to your most ur...

Page 26: ...Preface Technical Support xxvi 59265 02 B...

Page 27: ...e model 5802V has dual replaceable power supplies the model 5800V switch has a single non replaceable power supply This section describes the features and capabilities of the QLogic 5800V Series switc...

Page 28: ...about the switch s operational status These LEDs include the Input Power LED green Heartbeat LED green and the System Fault LED amber as shown in Figure 1 2 The Maintenance button shown in Figure 1 2...

Page 29: ...e maintenance button to reset the switch or to place the switch in maintenance mode Maintenance mode sets the IP address to 10 0 0 1 and provides access to the switch for maintenance purposes when fla...

Page 30: ...e is a passive cable and transceiver assembly that connect to other XPAK capable switches The XPAK ports come with covers that must be removed before installing transceivers or cables XPAK port LEDs a...

Page 31: ...In LED is not lit For more information about the Logged In LED refer to Logged In LED Indications on page 4 7 Port Activity LED Green The Activity LED indicates that data is passing through the port E...

Page 32: ...when connected to a single device or as an E_Port when connected to another switch If the device is a single device on a loop the GL_Port will attempt to configure first as an F_Port then if that fai...

Page 33: ...or a Linux workstation that is used to configure and manage the switch fabric You can manage the switch over an Ethernet connection using the CLI QuickTools or SNMP The Ethernet port has two LEDs the...

Page 34: ...e pins on the switch RS 232 connector are shown in Figure 1 6 and identified in Table 1 2 For information about connecting the management workstation through the serial port refer to Connect the Works...

Page 35: ...us LEDs as shown in Figure 1 7 The Power Supply Fault LED amber lights up to indicate that a power supply fault exists and requires attention The Power Supply Status LED green lights up to indicate th...

Page 36: ...h contains a Web applet called QuickTools QuickTools is best suited for fabrics with fewer than four switches For larger fabrics consider the optional management application Enterprise Fabric Suite Yo...

Page 37: ...tack management Performance View for port performance Extended Credits Wizard Zoning Wizard mPort Technology for moveable ports For more information about Enterprise Fabric Suite refer to the QLogic 5...

Page 38: ...ference Guide You must use the CLI to configure SNMP version 3 For more information about SNMP version 3 and the related commands refer to the Snmpv3user command in the QLogic 5800V Series Fibre Chann...

Page 39: ...number of devices will determine the number of ports that are needed and in turn the number of switches Consider the transmission speeds of your adapters and SFPs The switch ports 0 19 support 1Gbps...

Page 40: ...ally or as a group by creating an alias A zone can be a component of more than one zone set Several zone sets can be defined for a fabric but only one zone set can be active at one time The active zon...

Page 41: ...FP port is supported by a data buffer with a 16 credit capacity that is 16 maximum sized frames Table 2 2 lists the approximate transmission distances at full bandwidth over fiber optic cables With En...

Page 42: ...al rate of 20Gbps 5100MB bandwidth Multiple source ports can transmit to the same destination port if the destination bandwidth is greater than or equal to the combined source bandwidth For example tw...

Page 43: ...rise Fabric Suite on an unlimited number of workstations Enterprise Fabric Suite is available with a 30 day trial license on the CD that is included with the switch product The port activation license...

Page 44: ...e variety of topologies Consider your topology and cabling requirements Optimizing Device Performance When choosing a topology for a multiple chassis fabric consider the proximity of your server and s...

Page 45: ...o 1 the domain ID lock set to False and the principal priority set to 254 For information about changing the default domain ID domain ID lock and principal priority parameters refer to the Set Config...

Page 46: ...een chassis in each direction which is equivalent to three SFP connections operating at 4Gbps Upgrading the XPAK ports to 20Gbps is equivalent to 3 SFP connections operating at 8Gbps Figure 2 1 shows...

Page 47: ...3 inch and three 9 inch XPAK switch stacking cables Eighty SFP ports are available for devices Figure 2 3 Four Switch Stack Figure 2 4 shows a five switch stack of model 5800V Series switches using f...

Page 48: ...P ports are available for devices Figure 2 5 Six Switch Stack Common Topologies Although QLogic recommends using the XPAK stacking ports to achieve the highest cabling efficiency and bandwidth you can...

Page 49: ...to any switch in the loop The loop also provides failover if a switch fails Using 24 port QLogic 5800V Series switches the cascade fabric shown in Figure 2 6 has the following characteristics Each cha...

Page 50: ...ries switches the mesh fabric shown in Figure 2 7 has the following characteristics Each link contributes up to 850MB of bandwidth between switches 1700MB in full duplex Because of multiple parallel p...

Page 51: ...wo Fibre Channel SFP ports are available for devices Figure 2 8 Multistage Topology Transparent Routing The transparent routing feature provides inter fabric routing to allow controlled and limited ac...

Page 52: ...remote fabric Local devices on the same QLogic 5800V Series Fibre Channel Switch can each be mapped to different remote fabrics For mappings between a specific QLogic 5800V Series Fibre Channel Switch...

Page 53: ...ect the TR_Port to the remote fabric The application prompts you to configure TR_Ports where existing port connections to remote fabrics have isolated For remote Brocade or Cisco fabrics the switch to...

Page 54: ...abrics are complete the transparent routing connection becomes active and the local devices will discover the remote devices Switch Services You can configure your switch to suit the demands of your e...

Page 55: ...ault is enabled Network Time Protocol NTP Provides for the synchronizing of switch and workstation dates and times through an NTP server Synchronizing the workstation time helps to prevent invalid SSL...

Page 56: ...accounts All users can change their own passwords Account names and passwords are always required when connecting to a switch Authentication of the user account and password can be performed locally u...

Page 57: ...e switch and the peer device Public key encryption requires a public key a corresponding private key and the necessary certificates to authenticate them Public key infrastructure PKI provides support...

Page 58: ...ide Consider your connection security requirements for the command line interface SSH management applications such as Enterprise Fabric Suite SSL or both Access to the device security menu selections...

Page 59: ...the device supports authentication When using a RADIUS server every switch in the fabric must have a network connection A RADIUS server can also be configured to authenticate user accounts as describ...

Page 60: ...is to secure F_Ports and E_Ports in the fabric Figure 2 9 Security Example Switches and Adapters Device Switch_1 WWN 10 00 00 c0 dd 07 e3 4c Security Yes Device Switch_2 WWN 10 00 00 c0 dd 07 e3 4e Se...

Page 61: ...or node WWN The type of switch WWN you use in the switch security database must be the same as that in the adapter security database For example if you specify a switch with a port WWN in the switch...

Page 62: ...e Security_Set_1 on Switch_1 4 Create a security set Security_Set_2 on Switch_2 Create an ISL group Group_ISL_2 in Security_Set_2 with Switch_2 and Switch_1 as members as shown in the following table...

Page 63: ...he switch to Radius_1 in the following cases Adapter_1 log in to Switch_1 Switch_1 log in to Switch_2 Switch_2 log in to Switch_1 Figure 2 10 Security Example RADIUS Server Device Switch_1 WWN 10 00 0...

Page 64: ...Set_1 with Switch_1 and Adapter_1 as members as shown in the following Device Authentication Order RadiusLocal Authenticate devices using the RADIUS server security database first If the RADIUS server...

Page 65: ...32 character hexadecimal or 16 character ASCI secrets The switch secret must be shared with the adapter security database b Create an ISL group Group_ISL_1 in Security_Set_1 with Switch_1 and Switch_...

Page 66: ..._1 and Switch_2 as members as shown in the following 6 Save and activate Security_Set_2 on Switch_2 Switch_2 Node WWN 10 00 00 c0 dd 07 e3 4e Authentication CHAP Primary Hash MD5 Primary Secret abcdef...

Page 67: ...objective is to secure the management server on Switch_2 from unauthorized access by an adapter or an associated host application Figure 2 11 Security Example Management Server Device Adapter_1 APP_1...

Page 68: ...ch with a port WWN in the switch security database you must also specify that switch in the adapter security database with the same port WWN For MD5 authentication create secrets as shown in the follo...

Page 69: ...ation QuickTools and the CLI reside in the switch firmware and manage individual switches in a single fabric Consider how many fabrics and switches will be managed how many management workstations are...

Page 70: ...2 Planning Fabric Management 2 32 59265 02 B...

Page 71: ...are covered Site Requirements Installing a Switch Installing Firmware Adding a Switch to an Existing Fabric Installing Feature License Keys Site Requirements Consider the following items when install...

Page 72: ...ntilation The switch requires the following operating conditions Operating temperature range 5 40 C 41 104 F Relative humidity 10 90 percent non condensing Table 3 1 Management Workstation Requirement...

Page 73: ...with the components shown in Figure 3 1 QLogic 5800V Series Fibre Channel switch 1 with firmware installed Power cord 1 model 5800V Power cords 2 model 5802V Rubber feet 4 CD ROM containing a 30 day t...

Page 74: ...a QLogic rail kit part number SB RACKKIT WARNING Mount switches in the rack so that the weight is distributed evenly An unevenly loaded rack can become unstable possibly resulting in equipment damage...

Page 75: ...ent that is compatible with the maximum rated ambient temperature For operating temperature information refer to Environmental on page A 7 Do not restrict chassis air flow Allow 16cm 6 5in minimum cle...

Page 76: ...overs To install XPAK switch stacking cables position the cable connectors with the circuit board toward the mid line of the respective switch faceplates as shown in Figure 3 3 When installing the 3 i...

Page 77: ...with the 10 0 0 subnet refer to the following instructions for your workstation Windows Workstation Do the following 1 Click the Start button and choose Settings Control Panel and then Network and Di...

Page 78: ...the following COM Port settings in the COM Properties window and then click OK Bits per second 9600 Data Bits 8 Parity None Stop Bits 1 Flow Control None For Linux a Set up minicom to use the serial...

Page 79: ...se lectrique dont les fils sont mal branch s peut cr er une tension dangereuse dans les pi ces m talliques du ch ssis switch Pour viter toute secousse lectrique s assurer que les fils sont correctemen...

Page 80: ...ter approximately one minute the POST starts and the Heartbeat LED is not lit 4 After approximately one minute the POST is complete and all LEDs are out except the Input Power LED and the Heartbeat LE...

Page 81: ...ction or a serial connection Choose a switch management method and then connect the management workstation to the switch in one of the following ways as shown in Figure 3 4 Indirect Ethernet connectio...

Page 82: ...he IP address and subnet mask from your network administrator 4 Open the QuickTools Wizards menu and select Configuration Wizard Follow the instructions to set the switch IP address and the password C...

Page 83: ...g Switch command to modify the switch configuration For example Switch admin config edit Switch admin config set config switch For more information about the CLI commands refer to the QLogic 5800V Ser...

Page 84: ...ible firmware versions refer to the Firmware Release Notes No changes are being made to switches in the fabric including powering up powering down disconnecting or connecting ISLs changing switch conf...

Page 85: ...allation on page 3 15 For a non disruptive activation enter the Image Fetch command to download the firmware image file from an FTP or TFTP server Enter the Image Unpack command to unpack the image fi...

Page 86: ...t sessions including any Telnet sessions When the firmware activation is complete you may log in to the switch again Do you want to continue y n y Press q and the ENTER key to abort this command 2 Cho...

Page 87: ...scribes a custom firmware installation with a non disruptive activation 1 Download the firmware image file from the workstation to the switch If your workstation has an FTP server type the Image Fetch...

Page 88: ...Fabric zoning is sent to the switch from the fabric All ports will be GL_Ports The default IP address 10 0 0 1 is assigned to the switch without a gateway or boot protocol configured RARP BOOTP and D...

Page 89: ...Menu and select Features 2 In the Feature Licenses dialog click Add 3 In the Add License Key dialog type the license key in the Key field 4 Click Get Description to display the upgrade description 5 C...

Page 90: ...3 Installation Installing Feature License Keys 3 20 59265 02 B...

Page 91: ...LED indications Power On Self Test Diagnostics describe the Heartbeat LED and the port Logged In LED indications Power Supply Diagnostics describe Power Supply Status LED and Power Supply Fault LED in...

Page 92: ...condition remains contact your authorized maintenance provider For a model 5802V if the condition remains continue 3 Inspect the power supplies Are the power supplies fully seated in their bays Yes Co...

Page 93: ...he Heartbeat LED shows a blink pattern that indicates an error and the System Fault LED lights up If there are non critical errors the switch disables the failed ports and flashes the associated Logge...

Page 94: ...ase the Maintenance button to reset the switch Figure 4 2 Internal Firmware Failure Blink Pattern Fatal POST Error Blink Pattern A system error blink pattern is three blinks followed by a two second p...

Page 95: ...h using Telnet Type one of the following on the command line telnet xxx xxx xxx xxx or telnet switchname where xxx xxx xxx xxx is the switch IP address and switchname is the switch name associated wit...

Page 96: ...a model 5802V inspect the Power Supply Fault LED on both power supplies Is the Power Supply Fault LED lit on either power supply Yes Replace the power supply If the condition remains continue No Cont...

Page 97: ...ng once per second A device is logging in to the port or the port is in the diagnostics state Flashing twice per second The port is down offline or an error has occurred If a Logged In LED is flashing...

Page 98: ...on the affected port Yes If device security is configured review the ISL group in the active security set to ensure that the membership includes the necessary ports and that the secrets on all switche...

Page 99: ...eset tab in QuickTools Compare the zone membership between the two active zone sets Are they the same Yes Contact your authorized maintenance provider No Deactivate one of the active zone sets or edit...

Page 100: ...windows the switch generates an alarm disables the affected port and changes the port operational state to down Port errors can be caused by the following Triggers are too low or the sample window is...

Page 101: ...intenance provider Otherwise continue 3 Replace the Fibre Channel port cable Is the problem corrected Yes Complete No Continue 4 Inspect the device to which the affected port is connected and confirm...

Page 102: ...that has the same air flow direction Air flow direction is indicated on the power supply part number label Refer to Power Supply Removal and Replacement on page 5 2 For single power supply model 5800...

Page 103: ...iguration in Maintenance Mode Option 2 Resetting User Accounts in Maintenance Mode Option 3 Copying Log Files in Maintenance Mode Option 4 Removing the Switch Configuration in Maintenance Mode Option...

Page 104: ...nd release the Maintenance button or power cycle the switch Unpacking a Firmware Image File in Maintenance Mode Option 1 The Image Unpack option unpacks and installs new firmware when the current firm...

Page 105: ...ts to Default option restores the password for the Admin account name to the default password and removes all other user accounts from the switch Copying Log Files in Maintenance Mode Option 4 The Cop...

Page 106: ...h in Maintenance Mode Option 7 The Reset Switch option closes the Telnet session exits maintenance mode and reboots the switch using the current switch configuration All unpacked firmware image files...

Page 107: ...n on the affected port will be interrupted until the transceiver is installed To remove a transceiver gently press the transceiver into the port to release the tension pull the release tab or lever an...

Page 108: ...The part number label on the power supply indicates the air flow direction When removing or replacing a power supply on an operating switch be sure that the Heartbeat LED is blinking once per second n...

Page 109: ...rm that the new power supply is compatible with the switch air flow direction The part number label on the power supply indicates the air flow direction as shown in Figure 5 2 Figure 5 2 Power Supply...

Page 110: ...5 Removal Replacement Power Supply Removal and Replacement 5 4 59265 02 B...

Page 111: ...s for the QLogic 5800V Series Fibre Channel switch To locate all connections switches controls and components refer to Section 1 Fabric Specifications Maintainability Fabric Management Dimensions Elec...

Page 112: ...C VI FC SW 4 Fibre Channel Element MIB RFC 2837 Fibre Alliance MIB Version 4 0 Fibre Channel Classes of Service Classes 2 and 3 Modes of Operation Fibre Channel Classes 2 and 3 connectionless Port Typ...

Page 113: ...Fabric Port Speed Ports 0 19 Ports 20 23 1 0625 2 125 4 250 or 8 50Gbps 12 750 or 25 50Gbps Maximum Frame Size 2 148 bytes 2112 byte payload System Processor 400MHz 440EP processor Fabric Latency int...

Page 114: ...V only Management Methods Enterprise Fabric Suite graphical user interface QuickTools Web applet Command Line Interface Application Programming Interface SMI S GS 3 Management Server SNMP FTP TFTP Mai...

Page 115: ...s for additional regions countries as listed in Table A 1 Width Height Depth 17 432mm 19 inch rack mount 1 70 43 2mm 1U 19 69 500mm Weight Model 5800V Model 5802V 13 5lbs 6 1Kg 16 3lbs 7 4Kg Operating...

Page 116: ...HK Israel SI 32 Plug CPK 9000 IL Italy CEI 23 16 VII Plug CPK 9000 IT Japan JIS 8303 PSE Plug CPK 9000 JP Malaysia BS1363 A Plug CPK 9000 UKHK Middle East CEE 7 7 Plug CPK 9000 CEE New Zealand AS NZS...

Page 117: ...sing 10 95 non condensing Altitude Operating Non operating 0 3 048m 0 to 10 000 feet 0 15 240m 0 to 50 000 feet Vibration Operating Non operating IEC 68 2 6 5 5 500Hz 0 2g 3 axis dwell 2 200Hz 0 6g 3...

Page 118: ...ational Emissions Standards FCC Part 15 Class A USA ICES 003 Class A ITE Canada EN 55022 Level A EC CISPR 22 Class A international Environmental Standards RoHS 6 WEEE EU and Japan Voltage Fluctuations...

Page 119: ...ting each port or device individually An alias is not a zone and cannot have a zone or another alias as a member AL_PA Arbitrated Loop Physical Address Arbitrated Loop A Fibre Channel topology where p...

Page 120: ...3 Service A connection less Fibre Channel commu nication service where frames are not explicitly acknowledged and delivery is on a best effort basis Common Information Model An industry standard for d...

Page 121: ...NMP on a switch Fabric View File A file containing a set of fabrics that were opened and saved during a previous QuickTools or Enterprise Fabric Suite session FDMI See Fabric Device Management Interfa...

Page 122: ...rnet Key Exchange IKE A protocol that automates the sharing of encryption keys and algorithms through the configuration of matching IP security associations on the switch and on the connected device o...

Page 123: ...ST Power on self test Power On Self Test Diagnostics that the switch chassis performs at start up to test its components Principal Switch The switch in the fabric that manages domain ID assignments Pu...

Page 124: ...torage device that responds to an initi ator device TR_Port Transparent routing port A port type that uses the Fibre Channel industry standard NPIV to provide access to devices on a remote Brocade or...

Page 125: ...ch 5800V Series Zone A set of ports or devices grouped together to control the exchange of information Zone Set A set of zones grouped together The active zone set defines the zoning for a fabric Zoni...

Page 126: ...Installation Guide Stackable Fibre Channel Switch 5800V Series Glossary 8 59265 02 B...

Page 127: ...6 browser 3 2 buffer credit 2 3 A 3 C cable 10 100 Base T 3 11 10 100 Base T crossover 3 11 fibre optic 2 1 null modem F F DB9 3 11 XPAK switch stacking 3 6 Call Home service 2 17 cascade topology 2 1...

Page 128: ...4 3 fatal POST 4 4 port 4 10 Ethernet direct connection 3 11 indirect connection 3 11 port 1 7 F F_Port 1 6 fabric management 2 31 A 4 management workstation 3 2 point to point bandwidth A 3 port 1 6...

Page 129: ...7 power supply 1 9 System Fault 1 3 4 2 license key 1 4 3 19 Link Status LED 1 7 log file 4 15 Logged In LED 1 5 4 7 login limit 2 31 M maintainability A 4 maintenance interface A 4 menu 4 14 mode 1 3...

Page 130: ...Power Supply Status LED 1 9 4 12 Power on Self Test description 4 3 fatal error 4 4 principal priority 2 7 switch 2 7 processor 3 2 A 3 public key 2 19 Public Key Infrastructure 2 19 Q QuickTools ser...

Page 131: ...h add to fabric 3 18 configuration 3 12 management 1 10 management service 2 16 power up 3 10 recovery 4 13 reset 1 3 4 16 services 2 16 specifications A 2 upgrade 1 4 System Fault LED 1 3 4 2 system...

Page 132: ...stallation Guide Stackable Fibre Channel Switch 5800V Series Index 6 59265 02 B Z zone conflict 4 9 definition 2 2 zone set active 2 2 definition 2 2 zoning database 2 2 hardware enforced 2 2 limits 2...

Page 133: ......

Page 134: ...icrosoft Windows XP and Windows 2000 2003 and Internet Explorer are registered trademarks of Microsoft Corporation Netscape Navigator and Mozilla are trademarks or registered trademarks of Netscape Co...

Reviews: