Power Supply Removal and Replacement
Model 5802V power supplies are hot-pluggable: you can remove or install one of
the power supplies while the switch is operating without disrupting service. The
power supplies are also interchangeable; that is, the left and right power supplies
are the same unit.
When removing or replacing a power supply, consider the following:
The left and right power supplies are interchangeable. However, you must
orient the power supply so that the AC receptacle is on the right.
Both power supplies must have the same air flow direction. The part number
label on the power supply indicates the air flow direction.
When removing or replacing a power supply on an operating switch, be sure
that the Heartbeat LED is blinking once per second (normal operation), so
that the switch can correctly report the power supply status.
To remove a power supply, unplug the power supply, and then loosen the two
knurled fasteners with a cross-head screw driver, as shown in
. Grasp
the power supply handle, and then pull firmly to disengage the modular connector.
Slide the power supply out of its bay.
Figure 5-1. Power Supply Removal
CAUTION!
Both power supplies must have the same air flow direction to prevent the
switch from overheating.
To avoid overheating, do not operate the switch with one power supply
any longer than necessary.
Knurled
Fasteners
Power Supply 1
Power Supply 2
Summary of Contents for SANbox 5800V Series
Page 1: ...59265 02 B Installation Guide Stackable Fibre Channel Switch 5800V Series Firmware Version 8 0...
Page 26: ...Preface Technical Support xxvi 59265 02 B...
Page 70: ...2 Planning Fabric Management 2 32 59265 02 B...
Page 90: ...3 Installation Installing Feature License Keys 3 20 59265 02 B...
Page 110: ...5 Removal Replacement Power Supply Removal and Replacement 5 4 59265 02 B...
Page 126: ...Installation Guide Stackable Fibre Channel Switch 5800V Series Glossary 8 59265 02 B...
Page 133: ......