50
(Fig. 6)
2.2 Remove the screw which already fixed in motor shaft, then connect the safety
cable with motor shaft firmly by this screw. (See Fig 7)
Connect the wiring harness from the down rod to the receptacle from the
motor wire as Fig.8. After finished, hide the wire into down rod.
NOTE: Take out the end of the safety cable from downrod before lowering
the downrod onto motor hub. (See Fig 9)
Install the screws and washers in opposite directions from each other (2 sets
on each side) and make sure the screws and washers are tightened firmly
with a screwdriver. (See Fig 10
ASSEMBLY
HANGING THE FAN
Install the mounting bracket to the ceiling box, as shown in Fig 11 below. Rotate
the mounting bracket in different directions so that the bracket mounting holes
match the screw holes of the ceiling box.
Note: This mounting bracket is a standard cable box.If the mounting bracket
is installed at the outlet box, it should be installed on the outlet box with two
screws matching the outlet box itself, as shown in Fig 11.
This bracket can also be mounted to the wooden ceiling beam, and then the four
ST5x24 screws can be used to lock the corresponding holes on the left and right
sides of the bracket.
Note: The wooden ceiling beam must meet the tensile test of 30KG for installation,
as shown in Fig 12. It is also possible to install the mounting bracket directly to the
concrete ceiling and install four screws to the left and right corresponding holes
of the bracket to lock the ceiling, as shown in Fig 13.
GB
(Fig. 7)
(Fig. 8)
(Fig. 9)
(Fig. 10)
Safety cable
Downrod
Canopy
Wiring cover