After Each Use
1. Clean the hub insert and inside of the hub.
2. Empty water tank. Position Qleeno over a floor drain and hold Decrease Water Flow button down for 3 sec-
onds to empty clean water.
3. Clean brush/pad and squeegee ring.
Transporting Qleeno
CAUTION:
Do not attempt lifting the entire machine without assistance. If transporting Qleeno a short dis-
tance, simply tilt the machine back on the transport wheels.
1. Unlock handle support locks, fold handle to lowest position and re-lock handle supports.
2. Lift front of machine and roll Qleeno with weight supported on transport wheels.
TROUBLESHOOTING
Symptom
Corrective Action
Qleeno will not start
• Check electrical connection and fuse.
Control panel Warning Indicator Light is on
• Water tank is low. Empty dirty water and refill clean
water.
Qleeno makes beeping sound and shuts off
• Water tank is empty. Empty dirty water and refill
clean water.
Water will not flow after starting
• Check filters for clogging.
Qleeno leaks water
• Clean water tank seals.
• Verify Water Fill cap is tight and properly threaded.
• Check water pump on.
• Inspect water tank for damage.
Qleeno leaks water when lifted for transport
• Check both caps on water tank firmly sealed.
Qleeno drags or pulls in one direction while operating
• Adjust casters (see pg. 5)
MAINTENANCE
WARNING:
Do not remove the motor cover. Maintenance requiring removal of the cover should only be
performed by a qualified repair technician.
Changing the Fuse
Wait 15 minutes after shutting down before changing the fuse and attempting to restart the machine.
The fuse is a standard 115V/10A, and is located under the control panel, near the electrical connection.
8
!
!