background image

After Each Use

1. Clean the hub insert and inside of the hub.

2. Empty water tank.  Position Qleeno over a floor drain and hold Decrease Water Flow button down for 3 sec-

onds to empty clean water.

3. Clean brush/pad and squeegee ring. 

Transporting Qleeno

CAUTION:  

Do not attempt lifting the entire machine without assistance.  If transporting Qleeno a short dis-

tance, simply tilt the machine back on the transport wheels.

1. Unlock handle support locks, fold handle to lowest position and re-lock handle supports.

2. Lift front of machine and roll Qleeno with weight supported on transport wheels.

TROUBLESHOOTING

Symptom

Corrective Action

Qleeno will not start

• Check electrical connection and fuse.

Control panel Warning Indicator Light is on

• Water tank is low.  Empty dirty water and refill clean 

water.

Qleeno makes beeping sound and shuts off

• Water tank is empty.  Empty dirty water and refill 

clean water.

Water will not flow after starting

• Check filters for clogging. 

Qleeno leaks water

• Clean water tank seals.

• Verify Water Fill cap is tight and properly threaded.

• Check water pump on.

• Inspect water tank for damage.

Qleeno leaks water when lifted for transport

• Check both caps on water tank firmly sealed.

Qleeno drags or pulls in one direction while operating

• Adjust casters (see pg. 5)

MAINTENANCE

WARNING:  

Do not remove the motor cover.  Maintenance requiring removal of the cover should only be 

performed by a qualified repair technician.

Changing the Fuse

Wait 15 minutes after shutting down before changing the fuse and attempting to restart the machine.

The fuse is a standard 115V/10A, and is located under the control panel, near the electrical connection.

8

 

!

 

!

Summary of Contents for QS101

Page 1: ...d or operator shall have an understanding of the product its operating characteristics and safety instructions before operation For your safety read understand and follow the information provided with...

Page 2: ...damage Inspect the cord carefully if it becomes twisted bent crushed or is run over If damage is observed replace the cord before using Qleeno Do not use Qleeno to remove explosive or flammable mater...

Page 3: ...maintenance instructions may result in injury and damage to property Maintenance or service other than prescribed in this manual must be performed by qualified repair personnel CAUTION Do not use or...

Page 4: ...ken bent cracked or damaged parts are noted Any equipment that appears damaged in any way or operates abnormally shall be removed from service immediately It is recommended that an annual inspection b...

Page 5: ...Ensure that correct brush scouring pad is securely mounted to machine 5 Adjust casters to proper height ref page 6 6 Fill water tank with fresh water and chemical if desired NOTICE Follow chemical ma...

Page 6: ...fe ensure scouring pad is concentric with holder Unfolding the Handle Unlock handle support locks on both sides of handle raise handle to desired position and re lock handle supports Handle is adjusta...

Page 7: ...2 Scrubber Indicator Light 4 Water Flow Indicator Lights 7 Suction Indicator Light 5 Increase Water Flow 8 Warning Light red Normal Operation Best results can be obtained by always using a full tank...

Page 8: ...ht is on Water tank is low Empty dirty water and refill clean water Qleeno makes beeping sound and shuts off Water tank is empty Empty dirty water and refill clean water Water will not flow after star...

Page 9: ...sert Clean inside of hub 3 To reassemble hub mate grooves on hub insert with screws around hub seat insert fully and turn counterclock wise to lock in place Changing the Squeegee Ring 1 Remove brush o...

Page 10: ...and dirty water tank After First 100 Hours of Use Frequency of use and type of environment will dictate when some maintenence is performed Lubricate casters with silicone grease or spray Inspect entir...

Page 11: ...it includes 10 fuses 1 7 710 6 8105 102 Water Distributor 1 8 710 3 9916 106 Vacuum Tube Repair Kit 3 9 710 4 8500 106 Squeegee Ring Assembly 1 10 710 4 8501 108 Brush 1 11 710 3 9902 105 Caster Repai...

Page 12: ...before proceeding with shipment or repairs on the product In such cases the customer s sole and exclusive remedy for any breach or alleged breach of warranty is limited to the repair or replacement o...

Reviews: