___________________________________________________________________________________________________
Third Part
(edition-0106)
Primary Heat Exchanger
_______________________________________________________________
RIVA
FP
SERVICE MANUAL – REV A
2-2
8) Completely unscrew the connection J and
rotate the pipe I downwards freeing it from
the heat exchanger connection (Figure 4)
9) Remove the heat exchanger by sliding it
forwards.
10) Reassemble the boiler carrying out the
removal operations in reverse order. Fit the
clip F with the arrow pointing upwards as
illustrated in Figure 3.
3
Cleaning
If there are deposits of soot or dirt between the
blades of the heat exchanger, clean with a brush
or non-metallic bristle brush.
In any case, avoid any actions that can damage
the protective varnish with which the exchanger
has been covered.