Primary Circuit Flow Switch
_______________________________________________________________
RIVA
FP
SERVICE MANUAL – REV A
9
-2
4) Re-assemble the parts in reverse order of
removal. Refer to Figure 3 for the correct
wiring connectors on the switch.
C
D
Figure 4
B
Removal of the membrane
1) Remove the front and side panels of the case
and empty the primary circuit.
2) Remove the fork C that holds the micro-switch
housing D (Figure 4).
3) Unscrew the four screws E (see Figure 5)
open the hydraulic operator and remove the
membrane F.
F
G
H
E
Figure 5
4) Reassemble the parts in reverse order of
removal.
When assembling the membrane, ensure that
its concave side faces towards the actuator
plate G and the reference indicated aligns