___________________________________________________________________________________________________
Third Part
(edition-0106)
Primary Heat Exchanger
_______________________________________________________________
RIVA
FP
SERVICE MANUAL – REV A
2-1
1
Function
The primary heat exchanger A in Figure 1 has
the function of transferring heat produced from
combustion of the gas to the water circulating in
it.
A
Figure 1
The hydraulic circuit is composed of 8 elliptical
pipes connected in parallel (Figure 2).
Figure 2
2
Removal
1) Remove the case panels.
2) Empty the primary circuit.
3) Remove the sealed chamber lid.
4) Remove the front panel B of the combustion
chamber by unscrewing the screws C (Figure
3).
5) Remove the screw D and the deflector E.
6) Remove the clips F (Figure 3).
C
B
F
E
D
Figure 3
7) Loosen the connection G, rotate to the left and
then move downwards the pipe H freeing it
from the connection of the primary heat
exchanger (Figure 4).
G
H
I
J
Figure 4
Primary Heat Excanger
1) Function
2) Removal
3) Cleaning