INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO XL-G11S.X / BFG
21
4 Electrical Connection
4.3 Connection of modules
Use solar cables for the connection at the junction
box outlet.
Only interconnect connectors of the same type and
manufacturer.
Use minimum No. 12 AWG copper wires insulated for
a minimum of 90 °C for field connections.
Danger! Risk of fatal injury due to electric shock!
Ensure that all electrical components are in a proper,
dry, and safe condition.
SOLAR
click
Ensure for a tight connection between the plugs.
Plugs click together audibly.
Do not connect modules with different orientations or
angles of inclination in the same string.
Note! Module damage may occur!
Ensure that the cabling is not under mechanical stress
(Comply with bending radius of ≥ 2.36 in (60 mm)).
Ensure that the cables do not run between module
and mounting rail or structure (danger of pinch).
Position the wiring on the solar modules that addi-
tional shading is avoided.