1 Introduction
Validity
These instructions are only valid for crystalline solar modules
from the company Qcells as specified at chapter "2.1 Technical
specifications". Qcells assumes no liability for damage resulting
from failure to observe these instructions.
Please observe the wiring and dimensioning of the system.
The installer of the system is responsible for compliance with
all necessary safety regulations during set-up and installation.
Qcells assumes no liability on the basis of these instructions.
Qcells is only liable in the context of contractual agreements or
in the context of accepted guarantees. Qcells accepts no other
responsibility for the functionality and safety of the modules.
Please observe the instructions for any other system
components that may be part of the complete solar power
system. It may be necessary to carry out a structural analysis
for the entire project.
Additional information for the Operator
Please keep this manual for the entire life of the solar power
system.
Please contact your system supplier for information concerning
the formal requirements for solar power systems.
Please be sure to contact the relevant local authorities
and energy providers regarding regulations and permit
requirements prior to installation of the solar power system.
Your financial success depends on the fulfillment of these
requirements.
Other applicable documents
In addition to this Manual following technical information are
relevant:
Document type
Product data sheet
Packaging and transport information
MISUSE OR INCORRECT USE OF SOLAR MODULES VOIDS
THE LIMITED WARRANTY AND MAY CREATE A SAFETY
HAZARD AND RISK PROPERTY DAMAGE. THIS INCLUDES
IMPROPER INSTALLATION OR CONFIGURATION, IMPROPER
MAINTENANCE, UNINTENDED USE, AND UNAUTHORIZED
MODIFICATION.
2 Planning
2.1 Technical specifications
For additional information see the relevant datasheet of the module provided at www.qcells.com.
PRODUCT LINE
Q.PEAK DUO M-G11
Q.PEAK DUO M-G11+
Q.PEAK DUO BLK M-G11
Q.PEAK DUO BLK M-G11+
Type
Q.ANTUM DUO Z
Length
1692mm
Width
1134 mm
Frame height
30 mm
Area
1.92 m²
Weight
21.2 kg
Max. system voltage V
SYS
1000 V
Max. reverse current
25 A
Permissible temperature range
–40 °C to +85 °C (–40 °F to +185 °F)
Junction box protection class
IP67 with bypass diode
Connector protection class
IP68
Fire rating based on ANSI / UL 61730
C / Type 2
Max. test load Push / Pull
1
5,400 Pa / 3,600 Pa
Max. design load Push / Pull
1
3,600 Pa / 2,400 Pa
Certificates
CE-compliant; IEC 61215:2016; IEC 61730:2016; PV module classification: Class II;
QCPV
1
Test and design load in accordance with IEC 61215:2016, depending on mounting options (see section "2.3 Mounting options")
ASYMMETRIC Q.PEAK DUO M-G11 30T
1134 mm
980 mm
1692 mm
30 mm
4 × Mounting slots (DETAIL A)
8 × Drainage holes
3 × 6 mm
Frame
1092 mm
AU/
EN
356 mm
Label
4 × Grounding points ø 4.5 mm
DETAIL A
16 mm
8.5 mm
21.1
mm
≥1250
mm
≥1250
mm
Fig. 1:
External dimensions and components for Q.PEAK DUO M-G11 Q.PEAK DUO BLK M-G11
Q.PEAK DUO M-G11+ Q.PEAK DUO BLK M-G11+
Attention!
This marking indicates that this product should not be disposed
of with other household waste within the EU. Recycle this product
properly to prevent possible damage to the environment or
a risk to human health via uncontrolled waste disposal and in
order to promote the sustainable reuse of material resources.
Please return your used product to an appropriate collection
point or contact the retailer where you purchased this product.
Your retailer will accept used products and return them to an
environmentally-sound recycling facility.