INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO M-G11.X

INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PEAK DUO M-G11.X

8

9

2 Planning

2.3 Mounting options

Specifications

MOUNTING

OPTION

POSITION OF CLAMPS* [MM]

TEST LOAD 

PUSH / PULL** [Pa] 

DESIGN LOAD 

PUSH / PULL** [Pa] 

SAFETY 

FACTOR

CL1a

100 - 450

5400 / 3600

3600 / 2400

1.5

20 - 570

2400 / 2400

1600 / 1600

CL1b

200 - 350

2400 / 3300

1600 / 2200

CL2a

20 - 150****

2400 / 2400

1600 / 1600

CL2b

20 - 200

2400 / 2400

1600 / 1600

CL3

200 - 350

3600 / 3600

3600 / 2400

CL5

short side: 20 - 100

long side: 300 - 450

3000 / 3000

2000 / 2000

FB1

356

5400 / 3600

3600 / 2400

FB2

356

3000 / 3000

2000 / 2000

IP1

-

  The below mounting options are only possible under certain conditions.

MOUNTING

OPTION

POSITION OF CLAMPS* [MM]

TEST LOAD 

PUSH / PULL*** [Pa] 

DESIGN LOAD 

PUSH / PULL*** [Pa]

SAFETY 

FACTOR

CL1b

20 - 550

1600 / 2400

1060 / 1600

1.5

CL2a

20 - 350****

2400 / 2000

1600 / 1330

IP2

-

2400 / 1800

1600 / 1200

** 

***

****

Distance between outer edge of module and middle of the clamp; consider further details below.

Loads according to IEC 61215-2:2016 and UL 61730-2:2020

Test procedure according to IEC 61215-2:2016 and UL 61730-2:2020. Loads for these mounting options do not fulfill the 

requirements of the standards.

Rails must not be under the junction box.

2 Planning

2.3 Mounting options

MOUNTING 

OPTION

REQUIREMENTS

All

  The loads in the table are related to the mechanical stability of the solar modules. The mechanical 

stability of the mounting system including clamps has to be evaluated by the system supplier. The 

listed test load values have been determined with the following clamp parameters: clamp width = 

40 mm and clamp depth = 10 mm.

  The system installer is responsible for the determination of location-specific load requirements.

  Ensure, that the connection cables of the junction box do not run between laminate and mounting 

rails.

  Modules bend under load. Therefore, sharp objects (e.g. screws, ballast stones, rail ends, rails 

with burrs or sharp corners) must not be placed near the module backside so as not to touch the 

laminate under load.

  Ensure that the junction boxes do not touch the mounting structure (e.g. shorts rails, ballast, etc.) 

or the rooftop under load. Clamps or insertion profiles etc. must not touch the glass (even under 

load).

  Unbalanced loads (e.g. snow overhangs, snowdrifts) which result in locally significantly increased 

loads must be removed or avoided by technical measures.

CL1a, CL2a, CL3,

FB1, FB2

  Ensure that module frame is fixed directly on the rail of the substructure (no spacer allowed 

between the module and substructure).

CL1b

  Using of short mounting rails are permissible, if they overlap with the module less than 210 mm. 

Maintain a minimum distance (clearance) of ≥ 35 mm between frame bottom edge and roof top or 

ballast.

CL1b, CL2b, CL3, FB2

  Minimum support depth of 15 mm is required on the back side of the module.

CL5

  Minimum required support depth on the module backside is 10 mm on long frame side and 15 mm 

on short frame side.

IP1, IP2

  Ensure minimum support depth of 15 mm on the backside and 10 mm on the front side of the 

module.

FB1, FB2

  Use M8 corrosion-proof screws and washers (diameter ≥ 15.8 mm) for mounting slots (Detail A, 

Fig.1). Mounting screws and washers should have the same material properties.

Summary of Contents for Q.PEAK DUO BLK M-G11

Page 1: ...Installation and operation manual Q PEAK DUO M G11 X solar module series...

Page 2: ...the solar modules This manual Other applicable stipulations such as country specific regulations for pressure equipment operational safety hazardous goods and environmental protection Regulations and...

Page 3: ...WARRANTY AND MAY CREATE A SAFETY HAZARD AND RISK PROPERTY DAMAGE THIS INCLUDES IMPROPER INSTALLATION OR CONFIGURATION IMPROPER MAINTENANCE UNINTENDED USE AND UNAUTHORIZED MODIFICATION 2 Planning 2 1 T...

Page 4: ...the ground the roof or the fa ade Forces acting on the module are relayed to the mounting substructure Ensures sufficient rear ventilation of the module Avoid the usage of different metals to prevent...

Page 5: ...values have been determined with the following clamp parameters clamp width 40mm and clamp depth 10mm The system installer is responsible for the determination of location specific load requirements...

Page 6: ...mum number of modules in the string Parallel Connection Modules may be damaged by the occurrence of reverse currents caused by module defects ground leaks or defective insulation Ensure that the maxim...

Page 7: ...tion cables or junction box Carry modules upright and horizontally as shown Note Module damage may occur Never step on modules Do not subject modules to any mechanical stress Do not allow any objects...

Page 8: ...ctric arcs may result from the separation of a closed circuit These can result in life threatening injuries The danger increases when several modules are connected in series Please be aware of that th...

Page 9: ...nly be performed by qualified and skilled personnel see page 3 Ensure correct polarity Use solar cables for the connection at the junction box outlet Only interconnect connectors of the same type and...

Page 10: ...7 Disposal Do not disconnect modules by yourself Please contact an installer or Qcells Technical Customer Service Department Dispose of modules in accordance with the local disposal regulations Ensure...

Page 11: ...ay occur Remove snow and ice carefully without force e g with a very soft broom Do not scratch off dirt Module cleaning has to be done by qualified personnel according to the state of the art and taki...

Page 12: ...manual solar modules Q PEAK_DUO_M G11 X_modules_series_30T_2022 07_Rev04_EN Hanwha Q CELLS GmbH OT Thalheim Sonnenallee 17 21 06766 Bitterfeld Wolfen Germany EMAIL WEB TEL FAX sales qcells com www qc...

Reviews: