© 2020 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com
Specification subject to change.
Rev-03-08-21
INSTALLATION
FLEX Light - FLEX Mini
NOTES:
• Field modifications must comply with Q-Tran’s installation methods otherwise warranty is null and void
Clasp Front Connector
Components
Tools
Please ignore these steps if the front connector has been assembled before delivery.
NOTE:
1. Never wet the assembly units or assemble with wet hands.
2. Please use the tools correctly.
3. Please pay attention to personal security when using tools.
NOTE:
Installation steps are the same for Vertical and Horizontal Bending, even though the LED locations
are different.
Inducer
Gripper
Feed Connector (1pc)
[Contain Silicone Gasket(1pc)]
Anti-skidding Clip (1pc)
U Steel Plate (1pc)
02
Finished Assembly View
Explosive View
Anti-Wicking Ferrule
The anti-wicking ferrule is located at 4.53" (±0.39" tolerance) from the connector on the cable.
For protection against water ingress from inside of cable wire and hence damage the light.
The removal of the anti-wicking ferrule will void the warranty.
NOTE: Unless otherwise stated, the tolerance is ±0.02".
1.18”
ø0.47”