© 2020 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com
Specification subject to change.
Rev-03-08-21
INSTALLATION
FLEX Light - FLEX Dome
NOTES:
• Field modifications must comply with Q-Tran’s installation methods otherwise warranty is null and void
Clasp Front Connector
Components
Tools
Please ignore these steps if the front connector has been assembled before delivery.
NOTE:
1. Never wet the assembly units or assemble with wet hands.
2. Please use the tools correctly.
3. Please pay attention to personal security when using tools.
NOTE:
The light ends are marked with either an 01 or an 02. Always make sure to use an identically
labeled connector for the appropriate direction.
Inducer
Gripper
Finished Assembly View
Explosive View
Feed Connector (1pc)
[Contain Silicone Gasket (1pc)]
Anti-skidding Clip (1pc)
U Steel Plate (1pc)
Anti-Wicking Ferrule
The anti-wicking ferrule is located at 4.53" (±0.20" tolerance) from the connector on the cable.
For protection against water ingress from inside of cable wire and hence damage the light.
The removal of the anti-wicking ferrule will void the warranty.
NOTE: Unless otherwise stated, the tolerance is ±0.02".
1.18”
ø0.47”