background image

16

17

INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PRO L-G4.1, Q.PRO L-G4.2, Q.PLUS L-G4.1, Q.PLUS L-G4.2 – EN

INSTALLATION AND OPERATION MANUAL SOLAR MODULES Q.PRO L-G4.1, Q.PRO L-G4.2, Q.PLUS L-G4.1, Q.PLUS L-G4.2 – EN

17

16

 

Ä

Use solar cables for the connection at 
the junction box outlet. 

 

Ä

Use the same, inverter-compatible plugs.

SOLAR

NOTE

! Module damage may occur!

 

Ä

Ensure that the cabling is not under 
stress.

 

Ä

Ensure that the cables do not run 
between module and subconstruction 
(danger of pinch).

 

Ä

Do not connect modules with different 
orientations or angles of inclination in 
the same string.

 

Ä

Ensure for a tight connection between 
the plugs. Plugs click together audibly.

Klick

DE

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Ensure that all electrical components are 
in a proper, dry, and safe condition.

4.3  Connection of modules

ELECTRICAL CONNECTION

• 

A module with min. 

 1,200 mm long 

cable in portrait orientation can be wired 
as a “2nd next neighbor”

 

“2nd next neighbor” - Wiring without a 
return cable.

‚

 Standard wiring with a return cable

Inverter

Inverter

1

2

 

Ä

Ensure that all necessary safety and 
functional tests have been carried out 
according to current industry standards.

NOTE

! Module damage may occur!

 

Ä

Ensure that the plug connections are 
secured away from any water-channelling 
surface.

 

Ä

Integrate the system into the existing 
lightening protection system in 
accordance with the applicable local 
regulations.

WARNING

! Fire Risk!

 

Ä

Do not use light concentrators (e.g. 
mirrors or lenses).

 

Ä

Ensure that the cabling is not exposed 
and/or hanging and is protected from dirt 
and moisture.

4.4  After installation

ELECTRICAL CONNECTION

Summary of Contents for Q.PRO L-G4.1

Page 1: ...Valid for Africa Asia Europe Latin America South America Q PRO L G4 1 Q PLUS L G4 1 Q PRO L G4 2 Q PLUS L G4 2 INSTALLATION AND OPERATION MANUAL...

Page 2: ...ocedure Prohibited Beware of possible danger or damage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to product Safety Regulations I...

Page 3: ...nancial success depends on the fulfillment of these requirements Other applicable documents In addition to this Manual following technical information are relevant DOCUMENT TYPE Product data sheet Pac...

Page 4: ...stipulations as well as with the following Conform to the necessary structural requirements Compliant with local snow and wind loads Properly fastened to the ground the roof or the fa ade Forces acti...

Page 5: ...a safety factor of 1 25 for the following Calculating the voltage measurement values Voc of components Calculating the current measurement values ISC of conductors Sizing of control systems connected...

Page 6: ...e the modules securely in cool and dry rooms The packaging is not weatherproof DANGER Risk of fatal injury due to electric shock Do not install damaged modules Inform your distributor of any damages i...

Page 7: ...ather DANGER Risk of fatal injury due to electric shock Only use dry insulated tools Do not carry out the installation alone Only install undamaged modules and components Do not modify the module e g...

Page 8: ...modules are disconnected at the inverter prior to separation Be sure to observe the specified time intervals after switching off the inverter High voltage components need time to discharge DANGER Risk...

Page 9: ...lectric shock Ensure that all electrical components are in a proper dry and safe condition 4 3 Connection of modules 4 ELECTRICAL CONNECTION A module with min 1 200mm long cable in portrait orientatio...

Page 10: ...a loss of performance Maintenance The system should be inspected by an installer annually to check the following all system components sit securely and are corrosion free the connection is secure and...

Page 11: ...lee 17 21 06766 Bitterfeld Wolfen Germany TEL 49 0 34946699 23222 FAX 49 0 34946699 23000 EMAIL service q cells com WEB www q cells com Subject to change without notice Hanwha Q CELLS Installation man...

Reviews: