DANGER!  
Risk of fatal injury due to electric shock!

When disconnecting an electric circuit carrying direct 
current, electric arcs can occur that may result in 
life-threatening injuries.

 

Ä

Do NOT unplug the cable when under load.

 

Ä

Do NOT connect any exposed cable ends.

 

Ä

Do NOT touch the poles at the same time.

A solar module generates electrical current and voltage 
even at a low intensity of illumination. Sparks and electric 
arcs may result from the separation of a closed circuit. 
These can result in life-threatening injuries. The danger 
increases when several modules are connected in series.

 

Ä

Please be aware of the entire open circuit voltage is 
active even at low levels of solar irradiation. 

 

Ä

Please follow the valid national regulations and safety 
guidelines for the installation of electrical devices and 
systems.

 

Ä

Please make sure to take all necessary safety precautions. 
With module or phase voltages of more than 120 V, the 
extra-low voltage range is exceeded.

 

Ä

Carry out work on the inverter and the wiring with extreme 
caution.

 

Ä

Ensure that the modules are disconnected at the inverter 
prior to separation.

 

Ä

Be  sure  to  observe  the  specified  time  intervals after 

switching off the inverter. High-voltage components 
need time to discharge.

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Never open the junction box.

 

Ä

Change of bypass diodes is only allowed 

by qualified and trained personnel in 

disconnected and covered state.

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Never touch live contacts with bare 
hands.

 

Ä

Do not touch the poles at the same 
time.

 

Ä

Cover connectors by suitable protective 
caps until installation.

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Insulate any exposed cable ends.

 

Ä

Only connect cables with plugs.

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Only use dry, insulated tools for electrical 
work.

4.1  Safety

ELECTRICAL CONNECTION

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Ensure correct polarity.

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Be sure to maintain the time intervals as 

specified by the inverter manufacturer 

between switching off the inverter and 
beginning any further work.

DANGER

! Risk of fatal injury due to electric 

shock! 

 

Ä

Never unplug the cable when under load.

1.

 Switch off the inverter.

OFF

EN

3.

 Switch off the DC circuit breaker.

 

Ä

Disconnect plugs by the use of 

appropriate and qualified tools of 

the manufacturer Tyco, Amphenol or 
Multi-Contact.

2.

 Cover the modules to be disconnected.

4.2  Electrical installation safety

ELECTRICAL CONNECTION

Summary of Contents for Q.PRO L-G4.1

Page 1: ...Valid for Africa Asia Europe Latin America South America Q PRO L G4 1 Q PLUS L G4 1 Q PRO L G4 2 Q PLUS L G4 2 INSTALLATION AND OPERATION MANUAL...

Page 2: ...ocedure Prohibited Beware of possible danger or damage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to product Safety Regulations I...

Page 3: ...nancial success depends on the fulfillment of these requirements Other applicable documents In addition to this Manual following technical information are relevant DOCUMENT TYPE Product data sheet Pac...

Page 4: ...stipulations as well as with the following Conform to the necessary structural requirements Compliant with local snow and wind loads Properly fastened to the ground the roof or the fa ade Forces acti...

Page 5: ...a safety factor of 1 25 for the following Calculating the voltage measurement values Voc of components Calculating the current measurement values ISC of conductors Sizing of control systems connected...

Page 6: ...e the modules securely in cool and dry rooms The packaging is not weatherproof DANGER Risk of fatal injury due to electric shock Do not install damaged modules Inform your distributor of any damages i...

Page 7: ...ather DANGER Risk of fatal injury due to electric shock Only use dry insulated tools Do not carry out the installation alone Only install undamaged modules and components Do not modify the module e g...

Page 8: ...modules are disconnected at the inverter prior to separation Be sure to observe the specified time intervals after switching off the inverter High voltage components need time to discharge DANGER Risk...

Page 9: ...lectric shock Ensure that all electrical components are in a proper dry and safe condition 4 3 Connection of modules 4 ELECTRICAL CONNECTION A module with min 1 200mm long cable in portrait orientatio...

Page 10: ...a loss of performance Maintenance The system should be inspected by an installer annually to check the following all system components sit securely and are corrosion free the connection is secure and...

Page 11: ...lee 17 21 06766 Bitterfeld Wolfen Germany TEL 49 0 34946699 23222 FAX 49 0 34946699 23000 EMAIL service q cells com WEB www q cells com Subject to change without notice Hanwha Q CELLS Installation man...

Reviews: