FUNCTIONS
Chime
Chime function applies to ‘day’ mode only and if selected will cause the panel to generate a three-note
sound when an entry/exit zone is triggered. This feature is to inform the occupants of the building that
some one has entered.
Event Log
The Atlas 4 control panel incorporates a memory log of the last 30 alarm events and is accessible
to both Users and the Engineer. It will record Fire, Intruder, Personal Attack and Tamper alarms and
also show if any of the 4 alarm zones have been triggered or omitted. The Engineer can set the
clearing of the log for either Engineer-only or Master User and Engineer.
Auto Re-set
After an alarm condition the panel will automatically reset itself when the bell timer has expired.
Any zones which still remain triggered at that time will be omitted automatically.
Walk test
The walk test function allows each of the set modes to be checked in order to verify that all the intruder
detectors on the alarm system are functioning correctly. When undergoing a walk test the Engineer or
Master User can choose which of the set-modes he wishes to test. Any zones used in that set-mode
will cause a chime at the RKP or extension speaker if they are triggered. Walk test events will be
stored in the event log.
Keypress
Timeout
There is a 60 second keypress timeout facility. If a key is not pressed within 60 seconds of the last
keypress the keypress buffer is cleared.
Duress
This feature allows the user to either set or unset the alarm with the last two digits of the code
reversed, this will then send a Duress Code to the Central Receiving Station.
The panel will appear normal when the duress code is active.
Programmable
Output (PGM)
The programmable output may be programmed for any of the following 7 options:
Remote LED Enable: This option will allow the PIR LED’s to be enabled during Walk test mode if they
have been originally disabled by removing the link pin. This option will only work if the PIR has a
remote LED enable facility.
Latch Memory: This feature is useful when more than one detector is connected to a single zone.
When the panel is set the LED's of any triggered detector on this zone will latch causing their LED's to
flash on and off when the panel is unset. This feature will only work if the PIR has a Latch Memory
facility.
5 Seconds Switch Output: This option will allow the programmable output to act as a momentary
switch. This could be used for example to unlock an external electronic door.
Panel Set / Unset Switch Output: By using this option the programmable output will switch as the panel
is set and unset. This may be used for example to electronically lock a door as the panel is set and
unlock it when the panel is unset.
Follow Zone: This option will allow the programmable output to switch on and off as the programmed
zone is entered and exited.
Follow Line Fail: This option will allow the programmable output to switch on when a line fail occurs
and switch off when the line is active again.
Follow Kiss Off: This option will allow the programmable output to switch on for a few seconds when a
communication kiss off has been successfully completed.