background image

7

7. USB-A Port

USB-A fast charging port is compatible with various fast charging protocols, with a maximum power 
of 24W. The USB fast charging module has load monitoring function. When all of 2 USB ports are 
used at the same time, the device will dynamically adjust the output voltage and current to ensure 
load safety.

8.USB-C Port

USB-C fast charging port is compatible with various charging protocols, with a maximum power of 
27W.
The USB fast charging port has functions of short circuit and over-current protections.

9.AC Output Port

The AC inverter has protection functions, such as overload protection, over-temperature protection, 
under-voltage protection, and over-voltage protection.  
If the protection is activated during use, remove the load and restart the AC switch.
The AC maximum output is 300VA. The protection will be activated after 15 seconds duration of 
1.3 times overload.Before use, ensure that the load power factor is over 0.8.

 

10.Fan

The intelligent air cooling of the device will start up or shut down based on the dynamic information 
such as internal temperature, output power and etc.

11.Charging Ports

The device is equipped with two charging ports which are quick charging and standard charging.
Power-on activation function is  available. If the charger is plugged in when the device is off, the 
system will automatically start up. When the charger is in place, the device cannot be shut down.
Charging with grid: the device has a 4A standard charger and a 12A quick charger,  which can be 
fully charged in 9 hours and 3 hours respectively.  
Charging with photovoltaic: the device can be charged with connection to the MPPT module of 
12V output platform.
Charging with vehicle cigarette lighter: the device can be charged with the cigarette lighter port of a 
vehicle with an engine displacement under 4.0L. The device’s charging capacity depends on the 
voltage of the lead-acid battery of the vehicle. When the voltage of the lead-acid battery is lower 
than or equal to the device’s battery voltage, charging will stop.
During charging, the equipment has over-voltage and over-current protection functions.

AR500’s Feature

Summary of Contents for amber rock

Page 1: ...User Manual 0 3 2022 V1 7 PORTABLE ENERGY STORAGE POWER...

Page 2: ...ontech will not bear any legal liability arising thereof Don t use components not provided or recommended by Pylontech This manual contains instructions on safety operation maintenance etc It is impor...

Page 3: ...ocal service center when maintenance is in need 7 The display of battery capacity level is only for reference Please refer to the actual condition 8 Do not wrap the battery while it is running 9 Do no...

Page 4: ...ficient power more than 3 bars of power left 3 Transport the battery in accordance with the local laws and regulations Properly package and firmly installation should be a must to prevent the battery...

Page 5: ...2 Function Instructions Functions of Product 4 AR500 s Feature 5 Charging Methods Charging with Utility Power 11 Charging with Vehicle Cigarette Lighter 12 Capacity Expansion 12 Charging with PV 13 U...

Page 6: ...n independent switch to control each output No Load Auto Shutdown Function When the charger is not in place and the output power of all ports remains less than 2 W for 40 minutes the system will shut...

Page 7: ...5 AR500 s Feature 1 2 3 4 6 5 7 8 9 10 11 12 13...

Page 8: ...priate for more ports DC JACK port is self protected and self restored without any indications 4 Cigarette Lighter Port The built in output port for vehicle cigarette lighter with a maximum output cur...

Page 9: ...air cooling of the device will start up or shut down based on the dynamic information such as internal temperature output power and etc 11 Charging Ports The device is equipped with two charging port...

Page 10: ...brighter mode press the button for the third time flashing mode for SOS helping will be activated briefly press the button for the fourth time and the LED light will go out the LED can be turned off w...

Page 11: ...on AC switch status When the battery is fully charged the symbol will be displayed Each bar refers to 20 of the capacity When the extendable battery pack is connected the LCD screen will display the s...

Page 12: ...e device will shut down all energy output until the battery level goes up to over 30 and the DC output will resume However the AC output still remains closed The AC output must be turned on manually w...

Page 13: ...and it takes less than 10 hours for the device to be fully charged 12A Fast charging connect the fast charging cable with the high power port and it takes less than 3 hours for the device to be fully...

Page 14: ...ansion pack under the device the expansion pack above the device Connect the cigarette lighter cable with the standard charging port Connect the portable power station with expansion pack through a co...

Page 15: ...with PV Standard charging connect the standard charging cable with the low power port Fast charging connect the fast charging cable with the high power port The photovoltaic panel charges the device...

Page 16: ...otection Threshold 12A DC JACK Max Current 2 Ports 3A in total Ports Number 1 Group 2 Ports USB Output Voltage 5V 12V Output Power Type A Max 24W Type C Max 27W Type of Connection USB Type A USB Type...

Page 17: ...erature 0 45 C Storage and Transportation Temperature Short Term 20 C 60 C Storage and Transportation Temperature Long Term 25 C 5 C Shelf Life Charge every 6 months Humidity 0 95 no condensing Altitu...

Page 18: ...bel on the device with the power source Positional shift may reduce the charging efficiency Q Why doesn t my phone display fast charging symbol when I use two USB A ports to charge it simultaneously A...

Reviews: