Intelligent Management Function
The device is equipped with BMS intelligent management function for real-time monitoring of data
like the voltage,current and temperature of the battery. And it also has protection functions for
over-voltage, over-current, over-temperature, under-voltage, under-temperature and fault detection.
When voltage of the battery pack or battery cell is lower than the set value, the system will
automatically shut down after 30 seconds of delay.
Integrated intelligent management function can monitor output status in real time and it doesn’t
need an independent switch to control each output.
No Load Auto-Shutdown Function
When the charger is not in place and the output power of all ports remains less than 2 W for 40
minutes, the system will shut down automatically.
Fault Detection Function
The battery will stop charging and discharging in the event of breakdown of components and
other malfunction, and the failure symbol will show on the screen. Users can shut down the device
after fault occurs.
Capacity Expansion Function
An extendable battery pack can be connected with the main battery to enlarge capacity.
When connect batteries in parallel, turn on the switch of extendable battery pack after its secure
connection.
When the connection is successful, the screen will show a relevant hint.