background image

5

Using the device

After turning on the device, the main window of the 

Menu

 appears on the 

screen. It describes the current status and selected active settings working at 
a given moment. The settings include, among other things, driver input signals
and temperatures of operating sensors.

If no DMX signal in the input is detected, the screen displays the 

No DMX 

Signal 

message. Under this message the running device operation mode 

option is displayed when it is not receiving a DMX signal, e.g.

 

Last value

 

and 

information regarding the master mode (its activation or deactivation).

If the device receives a DMX signal, a green 

DMX Signal OK

 

message will 

appear. Below, there is the starting DMX address of channels that is occupied 
by the signal sent by the PX252. Then, the driver operation mode is presented,
e.g. 

2x RGB

. The operating mode options can be changed in the 

Driver 

operation mode

 menu.

Screen layout depending on enabled options and connected devices

Description of the other messages displayed in the 

Menu 

screen:

Scene 1, Program 1, (…), Last value

 – currently set function in the sub-

menu of the 

Menu   

No DMX Signal

8

Summary of Contents for PX252

Page 1: ...PX252 Driver LED C C 6 x 350mA User manual...

Page 2: ...6 5 Program editing 17 6 6 Scene editing 19 6 7 Temperature limits 19 6 8 Date and time 21 6 9 Screen saving 21 6 10 Local settings 22 6 11 PWM frequency 23 6 12 DMX output 23 6 12 1 Break Time 24 6 1...

Page 3: ...rves the right to make modifications in order to improve device operation PXM Marek upnik sp k Pod e 654 32 003 Pod e BDO register number 000005972 tel 48 12 385 83 06 mail info pxm pl www pxm pl Rev...

Page 4: ...on The PX252 can be either controlled from DMX protocol or act independently In this case the user have 8 fully programmable scenes and 8 programs Both of them can also be abundantly changed where suc...

Page 5: ...however during its installation and use the following rules must be strictly observed 1 The device may only be connected to 12 48V DC with current carrying capacity compatible with technical data 2 Al...

Page 6: ...9 The device cannot be use in places with temperature lower than 2 C or higher than 40 C 10 Clean with damp duster only 3 Connectors and control elements 6 DMX input DMX output Temperature sensors Con...

Page 7: ...Summary screen scrolls the menu to the top or to the left in the horizontal menu scrolls the menu to the bottom or to the right in the horizontal menu allows for entering a selected device option and...

Page 8: ...is not receiving a DMX signal e g Last value and information regarding the master mode its activation or deactivation If the device receives a DMX signal a green DMX Signal OK message will appear Belo...

Page 9: ...rk follow the instructions on the screen After disconnecting the power supply and connecting the cables to the following joints correctly OUT1 OUT6 the device can be turned on again 6 Programming devi...

Page 10: ...in accordance with your needs To do this select the or keys located on the screen and set an appropriate DMX address value confirming it using the enter button After changing the value save your setti...

Page 11: ...hannels RGBD colors red green and blue on 3 consecutive DMX channels Dimmer on 4 channel RGBWD colors red green blue and white on 4 consecutive DMX channels Dimmer on 5 channel RGBWAD colors red green...

Page 12: ...in this mode the driver can control up to 3 lamps color temperature adjustment from cold to warm WC Dyn a lamp with cold and warm white LEDs color adjustment on the first channel with the dimming fun...

Page 13: ...LEDs obtained on a given channel and thus determining the range of colors lit by the operated lamps To enable this option check the Channel balance off and confirm it by pressing enter The backlight...

Page 14: ...this menu it is possible to set the device s response to no DMX signal which controls LEDs An interesting option is the possibility to activate the astronomical clock It allows for turning on and off...

Page 15: ...available programs programmable in the Program editing menu if the driver does not detect the DMX signal To change the number of the displayed program follow the instructions shown in the preceding po...

Page 16: ...r The last two lines on the screen are the manually set time at which the options described above can be enabled and disabled The green and red backgrounds include boxes responsible for turning on or...

Page 17: ...ourse of a particular program which will be used later if the driver operates in the no DMX signal mode The menu consists of three columns The first one enables a program that we want to edit The next...

Page 18: ...hanges to the settings of all parameters of a given column in which this function is located XF xfade fade time the time of dimming LEDs ST scene time the length of scene entry in milliseconds Cont En...

Page 19: ...scribed in the item 6 5 Program editing 6 7 Temperature limits This option allows for setting a temperature value which if reached limits power consumption or turns off the device powered by the drive...

Page 20: ...previous items of the instructions e g 6 5 Program editing The Limit option allows for disabling the LED light power limitation function based on a temperature sensor in spite of the set temperature...

Page 21: ...expressed respectively in years months and days Remember to save your settings by selecting and confirm by pressing enter 6 9 Screen saving In this menu it is possible to activate the screen saving m...

Page 22: ...he device according to geographical coordinates longitude and latitude and the time zone in which the device operates To set appropriate parameters use the or buttons located next to a respective valu...

Page 23: ...sant flicker effect caused by improper synchronization of the LEDs control signal This option is useful if TV cameras are present 6 12 DMX output After selecting the DMX output submenu the current set...

Page 24: ...need to select floppy disc button and press enter 6 12 2 MAB Time Mark After Brake is the interval time occurs in each package according to the standard DMX 512 To save the value before leaving level...

Page 25: ...me between packets Its length can range from 16 to 5000 s To save the value before leaving level up in menu you need to select floppy disc button and press enter 6 12 5 Channels number Using this feat...

Page 26: ...white bar the height of which varies proportionally according to the following dependence the greatest height DMX signal value is 255 no bar DMX signal value is 0 DMX channels are described on the lef...

Page 27: ...er Time smoothing this function allows for making a time criterion for smoothing the DMX signal received by a lamp After confirming the message by pressing the enter button the User can select the tim...

Page 28: ...swiring is detected an appropriate message will appear on screen Before switching on the unit again check and correct wiring connections If the connection test function is disabled PX252 will not chec...

Page 29: ...mode with no branches on DMX control cable That means that DMX line from the signal source must be connected to DMX IN pins of PX252 and later directly from DMX OUT pins to the next device in DMX cha...

Page 30: ...number of LEDs n number of LEDs n number of LEDs n number of LEDs n Output circuits may not be combined with each other at any point DMX Controller PX252 6x350mA Power supply 12 48V DC V V L N Tempera...

Page 31: ...utput 1 512 channels number of output channels 6 programmable scenes 8 number of programs 8 control accuracy 16 bit output load 350mA MASTER SLAVE mode yes output sockets screw terminals USB weight 0...

Page 32: ...0 2018 EN 61000 4 2 2009 EN IEC 61000 6 1 2019 EN 61000 6 3 2007 and meets the essential requirements of the following directives 2011 65 UE DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of...

Reviews: