background image

MANUAL

LED Driver

3 x 6A OC

PX282

R

PiXiMo 18

Summary of Contents for PiXiMo 18

Page 1: ...MANUAL LED Driver 3 x 6A OC PX282 R PiXiMo 18 ...

Page 2: ...n of programs 12 Light control frequency 13 Screen saving screen blanking 14 Smooth 15 Default settings and memory error Err 16 Exceeding the maximum load 17 CPU temperature 18 RDM 19 20 21 Dimensions 22 Technical specification 23 Declaration of conformity Programming Connections scheme Manufacturer reserves the right to make modifications in order to improve device operation PXM Marek Żupnik spół...

Page 3: ...voltage and a high level of current carrying capacity 6A enable activating large quantities of LEDs PX282 can be controlled by the DMX signal or it can work independently In such operation mode the user has access to a fully programmable scene and 18 default sequences for which he can also change the playback speed and the smoothness of transition of particular steps With the use of 16 bit resolut...

Page 4: ...OUR etc no DMX signal response method selection MASTER SLAVE mode settings LIGHTNESS COLOUR control mode RGB control mode all outputs at 100 setting parameters for all channels simultaneously V 3 2 1 4 5 1 DMX 512 input 2 DMX 512 output 3 4 Display 5 Control outputs 6 Programming keys HSL control mode HUE SATURATION LIGHTNESS RGB Dimmer control mode Power supply 6 www pxm pl DMX IN DMX OUT GND GND...

Page 5: ...e on off DMX address settings for first channel all outputs off scene programme no 17 memory error message restore default device settings menu In case when MASTER feature is active dot in the lower right corner starts to blink with 0 25 Hz frequency When the PX282 is receiving DMX 512 signal it starts to blink with 4 times bigger frequency 1 Hz message about overloading Red channel when start add...

Page 6: ...it starts to blink with 2 times bigger frequency 0 5 Hz NOTE PX282 sends basically 3 channels R G B respectively but because the DMX standard specifies the number of channels being sent to a minimum of 24 these 3 basic channels are replicated eight times if need arises it is possible to replicate them on 512 channels not recommended due to lower transmission rate 5 DMX ADDRESS SETTING The menu of ...

Page 7: ...mode Desription of EFF mode is shown on next page The HSL mode Hue Saturation Lightness operates on three channels responsible for hue saturation and lightness respectively Working in the 3bd mode 4 channel 4 byte allows for setting each colour individually R red G green B blue and on the fourth channel the Dimmer function is implemented dimming all outputs In the 3 channel mode 3 byte each colour...

Page 8: ...rameter of a selected mode character no possibility to control a given parameter of a selected mode EFF mode effect channels desription CHANNEL1 RED CHANNEL2 GREEN CHANNEL3 BLUE CHANNEL5 SPEED CHANNEL6 FADE CHANNEL7 BRIGHTNESS x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Strobo 10 x x x x x Strobo 20 x x x x x Strobo 50 x x x x x...

Page 9: ... selecting the 2b mode a chosen value can be assigned only to addresses 1 and 2 For the rest from Ad3 up to Ad7 the device will display the message this means the address is out of the operating mode range ENTER NEXT NEXT ENTER ENTER NEXT NEXT You can also use the 18 preset programs It is also possible to set the reproduction speed and step change smoothness in the program for each of them To set ...

Page 10: ... 255 127 127 127 127 127 127 127 127 127 127 127 127 0 0 255 0 0 255 0 0 255 0 255 0 255 0 0 255 0 0 255 0 0 255 0 255 0 0 255 0 255 0 255 255 255 0 0 0 0 0 255 255 255 The following tables show the values for each output channel R G and B in programs from 1 up to 18 P01 P18 The value of 255 corresponds to the maximum lightness level on a given channel 127 50 of power level 0 full channel blanking...

Page 11: ...t are visible in video cameras To set the selected range of basic frequencies 1 Set the Frq function 2 Set the selected value using the next or previous buttons 11 ENTER NEXT 3x 13 SCREEN SAVING SCREEN BLANKING The device is equipped with a feature that allows for turning off the backlight This option is marked with the SCr sign With this feature the display is turned off after 5s if the keys of t...

Page 12: ...gnal packets for the selected option or the time interval set in the menu NEXT NEXT ENTER The smooth function may slightly slow down the lamp s response rate to changes in the DMX signal therefore it is possible to disable this option This can be done by checking the parameter and confirming the selection by pressing enter _ Time smooth enables changing the time parameter in which subsequent diffe...

Page 13: ... memory work control function If there are problems with the memory operation on the PX282 display the Err message appears memory error In this situation select the enter button The device will reload the default configuration and upload it to the memory If after this operation the message remains on the screen the memory is permanently damaged and the unit must be sent to the service point _ Err ...

Page 14: ...ed individual channels while the PX282 in the basic menu with address 1 Exceeding the load does not change on the rest of the segments of the display they displayed earlier message unchanged SUPPORTED_PARAMETERS all supported parameters PID 0x0050 PARAMETER_DESCRIPTION additional parameters description PID 0x0051 DEVICE_INFO information about device PID 0x0060 SOFTWARE_VERSION_LABEL firmware versi...

Page 15: ...n time mode TIM description in 14th point The default value is 0 Smooth off SMOOTH_TIME Smooth time for TIM function chosen in subsection above PID 0x801B Editable parameter Unit in ms Minimal value of this parameter is 10 and maximal 999 ms Default value is 200 NO_SIG_P1 18 SC_19 ON_20 OFF_21 choice of work mode for No DMX signal PID 0x801C Editable parameter Minimal Value is 1 maximal 21 For val...

Page 16: ...ź BALANCE ON OFF to activate or deactivate the balance of output channels PID 0x8025 Editable parameter A value of 0 is a balance off a value of 1 active balance The default value is set to 0 ź PWM_FREQENCY LEDs refresh frequency PID 0x8026 Editable parameter The minimum value is 366 and the maximum is 25000 The unit is Hz and the default value is 366 źSERIAL_NUMBER device serial number PID 0x8030...

Page 17: ...ows for moving backward within the selected menu 17 NEXT NEXT ENTER ENTER NEXT NEXT NEXT ENTER ENTER NEXT ENTER ENTER ENTER ENTER ENTER ENTER PREVIOUS NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT ENTER ENTER ENTER NEXT ENTER NEXT ENTER ENTER ENTER ENTER NEXT NEXT ENTER PREVIOUS NEXT NEXT NEXT NEXT NEXT ENTER NEXT NEXT NEXT PREVIOUS NEXT PREVIOUS NEXT ENTER NEXT PREVIOUS ENTER NEXT NEXT NEXT E...

Page 18: ... the modules in a chain this one and the subsequent modules will not respond to a DMX signal typical LED strip 12 24V DC power supply DMX controller to next modules GND DMX DMX 1 2 3 4 5 6 PX015 1 2 3 4 5 6 Chaser Scene Club 6p 90 100 80 70 60 50 40 30 20 10 0 100 90 80 70 60 50 40 30 20 10 0 Master Music Speed B G R 12 V V L N www pxm pl DMX IN DMX OUT GND GND OUTPUTS B G R PX282 12 24V DC R R R ...

Page 19: ...urrent consumption output channels number outputs load capacity control accuracy programmable scenes built in programs output sockets MASTER mode weight dimensions width heigth depth 22 TECHNICAL DATA 35 mm 90 mm 58 mm www pxm pl DMX IN DMX OUT GND GND OUTPUTS B G R PX282 DC IN The PX282 version equipped in 6A outputs and supporting RDM protocol has been introduced to the production starting from ...

Page 20: ...connectors Name of producer Manufacturer s address We declare that our product Product name Product code complies with the following standards LVD EMC Additional information Kraków 15 07 2014 DECLARATION OF CONFORMITY according to guide lines 2004 108 EC and 2006 95 EC stage and theatre consoles digital dimmers dmx systems architectural lighting controllers led lighting tel 48 12 626 46 92 fax 48 ...

Reviews: