SAVE / LOAD
After the equipment is set, the save operation must be performed so in case of power off the unit will keep the settings
On the System menu, select SAVECONFIGURATION > click SET
IMPORTANT :
The restore configuration and factory set buttons should not be used as it brings the unit in a
specific test mode not suitable for the final operation.
In case of need, you can restore the Default Best Settings by loading the default configuration file
from your USB Memory > CONFIGURATIONS FILES FOLDER > default configuration.
Use the LOCAL LOAD > BROWSE the wanted configuration file on the usb > UPLOAD
CAUTION : the preset file MUST MATCH the current version of software of the machine.
If you recall a preset file for a different version of software, the unit could become unstable and need
a FACTORY SET / SAVE / REPOWER then to set the parameters from scratch, or recall the proper preset file
To save the current settings to a file to restore on another unit, or to keep a backup, use the local save and rename
the .bin file as needed