7
FCIR HEATING ELEMENT
User manual
Figuresse Control IR • 2021-01-01
GB
DE
NL
CALIBRATING THE TEMPERATURE SPAN
The standard temperature span of the heating element is
30-60° C. It is possible to increase or decrease that span
by setting a maximum temperature of between 45° C and
65° C, (minimum temperature of 30° C stays unchanged). This
allows the user to achieve a maximum temperature which is
higher than the standard or to effectively heat a space with
the device during lower surrounding temperatures.
Example:
for the temperature regulation span of up to
45° C (30-45° C) modification by one step (one diode), means
increase/decrease of temperature by 3.75° C, while for the
temperature regulation span of up to 65° C (30-65° C) modifi-
cation by one step means increase/decrease by 8.75° C.
In order to modify the temperature span, unplug the device
and plug it back in, while pressing button. A single diode
will start blinking on the display panel. Use and but-
tons to set one of the 5 possible maximum temperatures.
The first diode stands for 45° C. The following diodes refer to
the following maximum temperatures: 50° C, 55° C, 60° C and
65° C.
After selecting the new temperature span press on/off but-
ton to store the new settings.
TROUBLE SHOOTING
PROBLEM
CAUSE
SOLUTION
The device is plugged in, no diodes are on.
Problem with the connection.
Problem with the connection.
Check the connection of the power wire, the plug
and the socket.
Heating element is not heating, outside diodes are
blinking alternately.
Overheating of device.
Check and confirm that the heating element’s
output does not exceed the recommended output
of your radiator. Check and reduce the water tem-
perature in the central heating system – must not
exceed 82°. In electric-only version check, if the
radiator is properly filled with the heating agent.
The device is heating despite turning it off with the
POWER button
.
Damaged electronics.
Disconnect the device completely, wait until the
radiator cools down and re-connect it.
PLEASE NOTE!
If the problem continues please contact your local distributor!