Purmo FCIR User Manual Download Page 6

6

FCIR HEATING ELEMENT 

User manual

Figuresse Control IR • 2021-01-01

GB

DE

NL

temperature regulation

dryer On/Off switch

IR sensor

Turning the device on with the   button will result in the 
radiator heating up to the set temperature. After reaching 
the set temperature the device will turn off and on regularly 
in order to maintain the set temperature.

The construction of the device as well as the physical char-
acteristics of the heating agent inside the radiator, influence 
the way in which the heat is distributed — the temperature 
of the bottom pipes on the radiator (especially the two lo-
cated at the very bottom of the radiator), may be lower than 
the temperature of the remaining parts of the radiator — this 
is a normal phenomenon.

TEMPERATURE INCREASE

In order to increase the temperature of the radiator, press  

 once or several times as required; the correct number of 

diodes will start blinking. The last blinking diode indicates 
the set temperature, whilst the last diode which shines 
constantly, indicates the current temperature. The remaining 
diodes will start shining constantly on reaching subsequent 
temperature levels.

TEMPERATURE DECREASE

In order to decrease the temperature of the radiator, press 

  once or several times as required; the correct number 

of diodes will start blinking. The last diode, which shines 
continuously, indicates the set temperature whilst the 
last blinking diode indicates the current temperature. The 
remaining diodes will start fading on reaching subsequent 
temperature levels.

ANTI-FREEZE FUNCTION

When the device is off and the temperature surrounding 
the temperature sensor drops to below 6° C, the device will 
switch on automatically. This is to prevent the heating agent 
inside the radiator from freezing. The activation of Anti-
freeze mode is indicated by the blinking of the middle diode.

DRYER FUNCTION

The Dryer turns the device on for 2 hours, e.g. in order to dry a 
towel. After this period of time the device automatically switches 
to the mode to which it was set before the dryer mode.

In order to activate the dryer mode, press and hold the   
button (also when the heating element is off) – the device 
will start working and maintain the most recent temper-
ature setting. You can now freely adjust desired temperature 
level (buttons   und   ). After 2 hrs heater will revert to the 
previous setting (before dryer function activation).

To use 2 hrs timer heating element must be switched off. 
Switch it on by pressing and holding   button. After 2 hrs 
heater will switch off automatically. 

Press   button at any time to interrupt the dryer mode.

REMOTE CONTROL MODE  

(WIRELESS COMMUNICATION) 

If the device is located in a room with an external IR control-
ler suitable for communication with the heating element, the 
first signal received by the heating element will automati-
cally activate the reception mode. The device will maintain 
the temperature indicated by the external controller while 
continuing to limit the radiator temperature so that it does 
not exceed 60°C. The remote control mode is indicated by 
the middle diode. In case of communication loss longer than 
25 minutes, the device will automatically switch back to 
the manual mode, and continue to operate according to the 
most recent setting. Any new signal received by the heating 
element, will switch it back to the remote control mode. 

The dryer function can be activated in the remote control 
mode (when the dryer function is deactivated, the heat-
ing element will resume the reception of signals from the 
external controller).

USE

Summary of Contents for FCIR

Page 1: ...Installation maintenance and operating manual FCIR Heating Element 2021 01 30 GB DE NL...

Page 2: ...OPERATE THE HEATING ELEMENT WITH BOTH VALVES CLOSED HINT Do not turn on the heating element and your cen tral heating at the same time DE SCHALTEN SIE DAS HEIZELEMENT NICHT EIN WENN BEIDE VENTILE GESC...

Page 3: ...nipolar cut off switch with a minimum contact opening of 3 mm for disconnecting the device on all poles 12 The device version labelled PB can be installed in bath rooms in zone 1 as defined by applica...

Page 4: ...9 Ensure that minors aged 8 and above or those with a physical or mental disability are supervised if operating the device 10 The device is not a toy Keep it out of the reach of chil dren 11 The devic...

Page 5: ...the subsequent guidelines when connecting the electrical installation a Brown wire live connection to the circuit L b Blue wire connect to neutral N c Yellow green wire earth connection PE 10 Before...

Page 6: ...automatically This is to prevent the heating agent inside the radiator from freezing The activation of Anti freeze mode is indicated by the blinking of the middle diode DRYER FUNCTION The Dryer turns...

Page 7: ...splay panel Use and but tons to set one of the 5 possible maximum temperatures The first diode stands for 45 C The following diodes refer to the following maximum temperatures 50 C 55 C 60 C and 65 C...

Page 8: ...um je 3 mm erm glicht 12 Die mit dem Symbol PB markierte Ger teversion kann im Badezimmer in der durch die angemessenen Vorschriften definierten Zone 1 installiert werden jedoch unter Einhalten der g...

Page 9: ...ist 9 Das Ger t kann von Kindern ab 8 Jahren oder Personen mit eingeschr nkter geistiger oder k rperlicher Leis tungsf higkeit nur unter Aufsicht oder nach Ausbildung in den Grunds tzen der sicheren...

Page 10: ...Anschluss an den Neutralleiter N c Gelb gr nes Kabel Anschluss an den Schutzleiter PE 10 Vor dem Bef llen des Heizk rpers stellen Sie bitte sicher dass die Verbindung zwischen der Heizpatrone und dem...

Page 11: ...nerhalb des Heizk rpers nicht einfriert Das Einschalten der Frostschutzfunktion signalisiert das Blinken der mittleren Diode TROCKENFUNKTION Die Trockenfunktion schaltet das Ger t f r 2 Stunden ein um...

Page 12: ...Die erste Diode zeigt die Temperatur von 45 C an Alle anderen wie folgt 50 C 55 C 60 C 65 C Nach dem Dr cken der Taste werden die Eingaben gespeichert Die Heizpatrone arbeitet nun mit den neuen Einste...

Page 13: ...13 FCIR HEIZPATRONE Gebrauchsanweisung Figuresse Control IR 2021 01 01 GB DE NL...

Page 14: ...omnipolaire onderbrekingsschakelaar te voorzien met een minimum contactopening van 3 mm voor het afschake len van het apparaat op alle polen 12 De uitvoering van het toestel met opschrift PB kan ge n...

Page 15: ...n de radiator open blijft staan 9 Zorg ervoor dat minderjarigen van 8 jaar en ouder of personen met een fysieke of mentale handicap onder toezicht staan bij het bedienen het apparaat 10 Het apparaat i...

Page 16: ...trische installatie a Bruine draad onder spanning aansluiten op het circuit L b Blauwe draad aansluiten op de nulgeleider N c Gele en groene draad aardverbinding PE 10 Voordat u de radiator met verwar...

Page 17: ...evriest De inscha keling van de antivriesfunctie wordt aangegeven door het knipperen van de middelste diode FUNCTIE DROGEN De Droger schakelt het apparaat gedurende 2 uur in bijv om een handdoek te dr...

Page 18: ...te stellen De eerste diode staat voor 45 C De volgende diodes staan voor de volgende maximum temperaturen 50 C 55 C 60 C en 65 C Na het selecteren van het nieuwe temperatuurbereik drukt u op de aan ui...

Page 19: ...19 FCIR VERWARMINGSELEMENT Gebruikshandleiding Figuresse Control IR 2021 01 01 GB DE NL...

Page 20: ...eation of this document No part of this document may be reproduced without the express written consent of Purmo Group Purmo Group accepts no responsibility for any inaccuracies or consequences arising...

Reviews: