Regeneration:
Current stage is showed in the lcd display
Programming:
The display shows all the internal parameters and
allows to modify them.
“MENU” KEY:
Allows entering inside the internal programing
and confirms the amended parameters in any stage of pro-
gramming .
“UP” Y “DOWN” KEYS:
Allow to navigate among the different
parameters. In programming allow to modify the selected pa-
rameters.
“REGEN” KEY:
It is used to start automatic regenerations.
PROGRAMMING BLOCKAGE:
After some seconds without pres-
sing any key the timer will be blocked automatically for safety.
The following message will be showed:
To unlock the timer, please press “MENU” key for 3 seconds.
6.4 Start-up programming
Denver softeners are configured to work with delayed regene-
rations (02.00 am).
ROGRAMMING:
1.
Connect the provided transformer to the electrical con-
nector at the back of the system. The timer will show service
position.
IMPORTANT:
After connecting the system can show fo-
llowing message:
12
This message indicates that the system is placing itself in
service position.If after two minutes this message is still in
the display please contact your distributor.
2.
Press “MENU” key for three seconds to enter into the inter-
nal programming. By pressing “UP” y “DOWN” keys the di-
fferent parameters can be selected,and pressing REGEN key
we can access to modify it (selected parameter flashes). With
“UP” y “DOWN” keys we can modify the selected parameter
and pressing REGEN key one final time the parameter will be
confirmed. Parameters that you can modify are as follows:
HOUR OF DAY:
Format 0:00-24:00.
LANGUAGE:
Spanish or English
UNITS :
Metric system or US units
TYPE OF REGENERATION:
There are several as follows:
Time initiated
(--)
Delayed regenerations according to selected
frequence (Ex: Regenerates every 3 days at 02:00 am ).
Meter immediate:
(MI)
Regenerations are stated as per treated
volume of treated water. When remaining volume is 0 starts a
regeneration.
Delayed regenerations:
(MD)
Regenerations are delayed accor-
ding to volume. When the remaining volume is finished the
system starts the regeneration the same day at the program-
med hour.
Mixed regeneration
(MR)
Similar to delayed regeneration but it
allows to program a máximum period of time between rege-
nerations.
NOTE:
Mixed regenerations are recommended. If you want
to select another type of regeneration, please contact
your distributor.
SYSTEM CAPACITY:
It is necessary to program the volume of
the water that can be treated by the system. To calculate it
please follow the indications as stated below:
Volume(m3) =
Exchange capacity (º HFxm3)
Hardness (º HF)
Where:
EXCHANGE CAPACITY:
It is the amount of hardness that can be retained by the sys-
tem. See the table below.
HARDNESS:
Hardness of inlet water in French degrees ºHF.
KEY LOCKED,
3S TO UNLOCK
INITIALIZING
6.
Installation
13