Gas Fired Tandoor Instruction Manual
Manual Rev. October 2019
Page | 8
•
Fixed pipe work must not be used with this appliance.
•
Connect tandoor to gas supply and conduct gas leakage tests to verify gastight
connections. Check entire piping system for leaks. A solution consisting of 50%
dishwashing detergent and water mix can be applied to all piping parts with a brush.
•
Matches, candles or other sources with open flames or sparks shall not be used for
this purpose. Gas controls are provided with outlet settings suitable for the fuel type
shown on the nameplate. Adjustments if needed to the regulator should only be
made by qualified service staff. The regulator outlet pressure must be the pressure
shown on the nameplate for the type of gas fuel used.
•
Some local codes require that a manual shutoff valve be installed in the same room
and within six feet of the appliance. If because of local code requirements, a manual
gas shutoff valve has to be installed on the appliance, and if it is mountedinside of
enclosure by access doors, a label should be provided indicating this construction.
•
Proper gas piping: In order to ensure proper performance of this unit as well as
other gas appliances on the same gas supply lines, a well-planned and properly sized
gas supply system is a must. If the appliances are to be connected to existing piping,
the piping should be checked for adequate capacity enabling full firing for all of the
units that are to use the piping run.
•
Pipe thread sealant (joint compound) shall be used sparingly and only on male
threads of pipe joint. Such compounds shall be resistant to the action of L.P. gases.
WARNING:
All pipefittings must be clean and free of dirt or other contaminants. Any
loose particles, such as dirt or metal filing, in gas lines can damage the controls and
affect operation.
•
Make certain not to obstruct the flow of combustion and ventilation air. Ensure that
air intake openings around the appliance jacket are not obstructed.
•
Appliance must be connected to suitable exhaust duct in compliance with all
applicable local codes.
•
Position the appliance to ensure that proper clearances for safety and service are
provided.
4.5.
Start up and operation
All appliances are operationally checked and adjusted before leaving our factory. These
adjustments are made to verify effective operation and that the appliance meets the
requirements of the test’s standards. At the installation site making sure all local codes
aremet is the responsibility of the installer.