www.PuriTandoors.co.uk
| ‘The Tandoor Clay Oven Ltd’ ta/ PURI Tandoors in UK
Gas Fired Tandoor Instruction Manual
Manual Rev. October 2019
Gas Fired Tandoori Oven
Instruction Manual
Page 1: ...www PuriTandoors co uk The Tandoor Clay Oven Ltd ta PURI Tandoors in UK Gas Fired Tandoor Instruction Manual Manual Rev October 2019 Gas Fired Tandoori Oven Instruction Manual ...
Page 2: ...he vicinity of this or any other appliance 2 A qualified installer must perform installation and service WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING If you smell gas 1 Shut off gas to the appliance 2 E...
Page 3: ...ilation 7 4 4 Gas supply and connection 7 4 5 Start up and operation 8 5 User instructions 9 5 1 Application of the oil 10 5 2 First firing 10 5 3 Shutting down of the appliance 11 6 Maintenance and cleaning of appliance 11 6 1 Servicing 11 6 2 General check 12 7 Component Replacement 12 7 1 Thermocouple 12 7 2 Ignite Electrode 13 7 3 Pilot Burner 13 7 4 Gas Tap Assembly 13 7 5 Burner 13 7 6 Injec...
Page 4: ... or the next day and let it burn for another 8 10 hours Finally the tandoor burner should be set on high gas 12 o clock position of knob for another 8 10 hours on the same day or the next day The clay walls will turn terracotta red after firing the tandoor for approx 25 30 hours after which the tandoor will be ready for cooking Salt water wipe This is to be done every other day before starting the...
Page 5: ...stalled by a technically qualified technician Ø At all times keep this manual in the vicinity of the oven Warning improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the following installation operation and maintenance instructions thoroughly before installing or servicing this equipment Continuous product improvement is a policy of The...
Page 6: ...ce for installation of gas catering appliances The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of psi 3 45kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping syste...
Page 7: ... operator access Do not block any louvered openings on appliance service panels 4 1 Unpacking Un crate the unit with extreme care do not use a hammer or heavy tools to un crate the unit Always remove shipping container parts and panels by only outward prying Make sure the unit is in the upright position before starting to un crate Before fixing the appliance in place remove all protective plastic ...
Page 8: ...o comply with the requirements of Approved Document J in the 1985 Building Regulations in Europe with a minimum area of 4 5 cm per 1Kwht 3412Btu per hr of total heat input Ventilation hood must be installed above the appliance according to all appliance codes by your local and state health and fire regulations It is required that the Tandoor be interlocked to the hood ventilation system There must...
Page 9: ...f this unit as well as other gas appliances on the same gas supply lines a well planned and properly sized gas supply system is a must If the appliances are to be connected to existing piping the piping should be checked for adequate capacity enabling full firing for all of the units that are to use the piping run Pipe thread sealant joint compound shall be used sparingly and only on male threads ...
Page 10: ...plate Only use rocks as supplied with the appliance see the diagram below 5 User instructions Make sure that the manual shutoff valve behind the unit is turned off and that the Tandoor gas valves are turned off Open the main gas line to the Tandoor oven On the appliance control valve depress and hold the back knob on the star position indicated by a star for 10 seconds to start pilot gas flow and ...
Page 11: ... they are installed The installation instructions shall specify that the gas supply tubing or hose shall comply with the national requirements in force and shall be periodically examined and replaced as necessary The type length which will not exceed 1 5 m and position of any flexible hose or tubing which may be used for supplying gas Unless otherwise stated the instructions indicate that the part...
Page 12: ...lied with the oven to effect repairs as follows when the Tandoor has cooled down Dampen the affected area with a moist cloth Fill in the crack with the clay provides using a spatula Smooth the foiled area with a soft moist cloth Allow repair to air dry for an hour DO NOT WET THE CLAY LINING Normal Cleaning Clean all the external panels with a non abrasive detergent To safely remove the build up of...
Page 13: ...onent Replacement 1 Only qualified persons should conduct service or repair of this equipment 2 Always disconnect power and fuel when repairing or servicing these appliances 3 Any service or repair conducted on the unit as covered by the warranty has to be authorized by the manufacturer 4 Only the original factory parts are to be used for any repair or replacement 5 If parts are lost or missing ob...
Page 14: ... bracket and replace 7 4 Gas Tap Assembly 1 Loosen and remove connections to burner pipe and gas inlet pipe 2 Loosen and remove connections to pilot burner 3 Loosen connection to thermocouple and remove 4 Loosen and remove the holding plate nut 5 Withdraw tap valve assembly 6 Replace as above in reverse order 7 5 Burner 1 Remove rocks and plate sitting on the burner 2 Loosen connection from burner...
Page 15: ...Min 9kW Net Injector fitted with 1 7 mm Medium Unit 28 x30 Natural Gas Rate at 20 mbar Max 16 5kW Net Min 6 5kW Net Injector fitted with 3 4 mm LPG Rate at 37 mbar Max 11 25kW Net Min 9kW Net Injector fitted with 1 7 mm Small Unit 24 x24 Natural Gas Rate at 20 mbar Max 16 5kW Net Min 6 5kW Net Injector fitted with 3 4 mm LPG Rate at 37 mbar Max 11 25kW Net Min 9kW Net Injector fitted with 1 7 mm P...
Page 16: ...Gas Fired Tandoor Instruction Manual Manual Rev October 2019 Page 15 Warning Labels ...