![puri Gas Fired Tandoori Oven Instruction Manual Download Page 7](http://html1.mh-extra.com/html/puri/gas-fired-tandoori-oven/gas-fired-tandoori-oven_instruction-manual_1627968007.webp)
Gas Fired Tandoor Instruction Manual
Manual Rev. October 2019
Page | 6
•
Refer to local codes for the building fresh air supply requirements in your respective
country.
•
Note: Where servicing may require greater access clearances than those shown on the
nameplate, then the greater clearances should be allowed for.
•
At installation, adequate clearances should be provided for proper operation and servicing
of theappliance and any field installed optional items. Data plate applies only to tandoor
oven as provided by appliance manufacturer
•
This appliance is for installation only at the clearances indicated on the name plate.
Clearances are specified from combustible and for non-combustible construction.
•
Observe clearances from combustible surfaces as marked on nameplate. Clearances
postedon unit are for safety reasons and lesser clearances cannot be applied. Additional
clearancesmight be required for service and operator access.
•
Do not block any louvered openings on appliance service panels.
4.1.
Unpacking
•
Un- crate the unit with extreme care, do not use a hammer or heavy tools to un-
crate the unit. Always remove shipping container parts and panels by only outward
prying.
•
Make sure the unit is in the upright position before starting to un- crate.
•
Before fixing the appliance in place, remove all protective plastic coating from the
unit.
•
Oven is on 4” (100mm) wheel castors and can be rolled out easily to the designated
installation area.
•
Unit must be rolled around by hand. Do not use a lift jack.
4.2.
Clearance and Positioning
•
This appliance requires a 6” (150mm) clearance from combustible and non-
combustible material and surfaces.
•
Never install propane appliances below grade.
•
A clear space, (rear clearance) of at least 6” (150mm) should be maintained at the
rear and sides of the appliance.
•
There must be minimum clearances of 750 mm in Europe, between top of the
appliance and any overhanging shelf. Shelves must be of non-combustible material.
•
It is recommended that the appliance is not installed in draughty locations or near
doors.