User Manual
9
" XXXXXXX " is display control command
(ASCII, max 48 byte).
/+ax:0123456
Configure
OFF
button:
Command Format
Description & Example
Feedback
/-Ax:XX XX XX XX
"x" represents the baud rate: x=0(2400)/
1(4800)/ 2(9600)/ 3(19200)/ 4(38400)/
5(57600)/ 6(115200).
" XX XX XX XX " is display control command
(HEX, max 48 byte).
For example: /-ax:30 31 32 33
XX XX XX XX
(30 31 32 33)
/-Ax:XXXXXXX
"x" represents the baud rate: x=0(2400)/
1(4800)/ 2(9600)/ 3(19200)/ 4(38400)/
5(57600)/ 6(115200).
" XXXXXXX " is display control command
(ASCII, max 48 byte).
/+ax:0123456
XXXXXXX
(0123456)
d)
Disconnect the control PC, then connect the display to the RS232 port.
e)
Press
ON
or
OFF
button to turn the display on or off.
2)
IR Learning
a)
Press
the
IR LEARNING
button to enable IR learning mode, the ON and OFF LEDs will
light up.
b)
Press one of the display control buttons, e.g. press
ON
button, and its LED will start to
flash.
c)
Point the display remote at the front panel built-in IR receiver and the press the Power
On button on the remote, and the ON LEDs will go dark.
d)
Repeat the above all three steps to set the
OFF
button function.
e)
Press
ON
or
OFF
button to turn the display on or off.
Summary of Contents for PT-PSW-41H
Page 26: ...User Manual ...
Page 27: ...User Manual ...