background image

User Manual

 

PT-MA-HD44M 

 

 2  

 

 

 

 
 
 

 

 

Summary of Contents for PT-MA-HD44M

Page 1: ...User Manual PT MA HD44M 1 User Manual 4x4 Matrix 4K 60Hz 4 4 4 HDR10 and Audio Extraction Model PT MA HD44M Designed in Germany 2021 PureLink GmbH All rights reserved VersionV1 0 ...

Page 2: ...g 6 Application Diagram 7 Remote Control Description 7 Panel Control Description 8 1 1 Video switch operation 8 1 2 Video control 9 1 3 Audio control interface 11 1 4 EDID setting interface 12 1 5 Preset application 14 1 6 Setup interface 15 1 7 Query information interface 18 RS232 Control 20 Command List 20 Web Control 21 Firmware Upgrade 25 After Sales Service 27 Asking for Assistance 28 ...

Page 3: ...rsons Do not dismantle the housing or modify the module It may result in electrical shock or burn Using supplies or parts not meeting the products specifications may cause damage deterioration or malfunction Refer all servicing to qualified service personnel To prevent fire or shock hazard do not expose the unit to rain moisture or install this product near water Do not put any heavy items on the ...

Page 4: ...Contents Please take an inventory of the package contents to ensure you have all the items listed below If anything is missing or damaged please contact your distributor for a replacement 1 x Main Unit PT MA HD44M 1 x Power Adaptor 12V 2A 1 x Remote control 1 x IR Ext RX Cable 5 x Phoenix 3 pin for RS232 cable termination L R Audio termination 1 x User Manual Specifications Operating Temperature 0...

Page 5: ...press to up LOCK Long press to lock long press again to unlock When locked all buttons is locked except for the lock button MENU Press for main menu interface or to return to the previous menu interface DOWN Short press for down ENTER Short press for confirm LCD screen Note Unit can be controlled by front panel button for simple operations such as video switching EDID control baud rate adjustment ...

Page 6: ... and Operating 1 Connect source devices to input ports of the matrix 2 Connect HDMI output ports to TV or other HDMI sink devices 3 Optional Connect RS232 cable from PC RS232 port 4 Optional Connect an Ethernet cable from the TCP IP port on the matrix to a local area network 5 Connect 12V POWER supply to DC power socket 6 Power on the matrix HDMI sources and displays ...

Page 7: ...Output 1 4 All outputs select INPUT Y a Press all button b Press INPUT Y button Y input 1 to 4 then INPUT Y switched to ALL OUTPUTS Turn off output channel PTP button Mirror all inputs and outputs Ex Input 1 to output 1 input 2 to output 2 etc Input 1 4 press output X then Input Y Switching input left and right Up down left and right control ...

Page 8: ...ill change according to the switching input and skip automatically if no input signal Panel Control Description 1 1 Video switch operation Signal switching includes 4 switching channels which can be randomly configured as input output according to requirements to form a 1 4 4 4 matrix It can switch any input signal to1 channel output or all channel output Operation format output channel input chan...

Page 9: ...and down button to choose Switching press ENTER to enter the next sub menu press the up and down button to select Output1 4 All means all output Switching the bottom color of the selected output turn to white press ENTER to enter the next sub menu press the up and down button to select input the bottom color of the selected input turn to white press ENTER button to complete video switching ...

Page 10: ... and down button to select On Off press ENTER button to enter the next sub menu Press up and down button to select output1 4 All means all output the bottom color of the selected output turn to white press ENTER to enter the next sub menu select Output HDMI1 4 press ENTER button to enter the next sub menu press the up and down button to select Off or On Press ENTER button to confirm that the outpu...

Page 11: ...ne channel HDMI output Operation 1 Select Audio in main menu and press ENTER button 2 press up and down button to select Line out press ENTER button the bottom color of the selected turn to white Able to select output1 4 and all via pressing up and down button press ENTER button to choose on and off 3 eg mute sound of TV which connected to HDMI output1 operation Audio ENTER Line out Output1 HDMI1 ...

Page 12: ...turns to white Able to select output1 4 and all via pressing up and down button press ENTER button to choose on and off eg turn off audio extraction of HDMI output1 operation Audio ENTER De Embed Output1 Off will return to upper menu after ENTER 1 4 EDID setting interface EDID management User EDID built in EDID Copy EDID mode The default EDID is Default1 Default1 4K60 444 LPCM 2 0 HDR HLG Default2...

Page 13: ...ss up and down button to select Input 1 All all inputs 3 press ENTER button to enter the next sub menu 4 press up and down button to select Default1 the bottom color of the selected turn to white press ENTER to complete setting 5 behind the selected EDID it will show the max supported resolution audio format and audio channel ...

Page 14: ...all Preset control interface has three sub menu Call scene Save scene Clear scene Operation select Preset in main menu and short press ENTER button to enter preset interface able to call save and clear preset save preset select Save anyone of Preset1 8 ENTER call preset Call any of the saved Preset1 8 ENTER clear preset Clear any of the saved Preset1 8 ENTER the saved preset will return to the def...

Page 15: ... Baud rate setting 4 options for baud rate setting 9600 19200 57600 115200 The default serial port is 115200 Below example is setting baud rate to 9600 Operation 1 Select Setup in main menu and press ENTER button 2 Press up and down button to select Baud 3 Press ENTER to enter the next sub menu 4 Press up and down button to select 9600 ...

Page 16: ...down button to select DHCP setting 3 Press ENTER to enter the next sub menu 4 Press up and down button to select On 5 Press ENTER to open DHCP to allocate IP address automatically Reboot Reboot device default is NO Operation select Setup in main menu and press ENTER button press up and down button to select Reboot press ENTER to enter the next sub menu press up and down button to select Yes press ...

Page 17: ... address can t be factory rest when under common 2 Factory All factory set for video switch EDID audio setting preset and device name Eg factory all operation select Setup in main menu and press ENTER button press up and down button to select Factory press ENTER to enter the next sub menu press up and down button to select ALL and press ENTER button press up and down button to select Yes and press...

Page 18: ... device name and version information IP interface query device IP address MAC address and DHCP status Operation select INFO in main menu and press ENTER button press up and down button to select System or IP bottom color will turn white when selected press ENTER to enter the next sub menu then able to query device information ...

Page 19: ...User Manual PT MA HD44M 1 ...

Page 20: ...hat connect to PC in parameter configuration area Baud Rate 115200 bps Default Parity None Data Bit 8 bit Stop Bit 1 bit Enter Port Command in Send options Command List 1 All commands start with 2 _ the underline cannot omit 3 Command head Parameter and target need to add one SPACE ...

Page 21: ... log in 192 168 1 168 Change IP address of PC Before configuring the device through the website it is necessary to configure the IP address of the computer configured with the device mainly to ensure that the computer and the device are set in the same network segment 1 Open the network control center and set the computer s IP address 2 Choose to use Static IP with the IP address set to 196 168 1 ...

Page 22: ...Manual PT MA HD44M 2 Log in by browser Type in user name and password default user name admin default password admin Note suggest to use latest version of Google firefox IE11 browser for better compatibility ...

Page 23: ...User Manual PT MA HD44M 2 ...

Page 24: ...User Manual PT MA HD44M 2 ...

Page 25: ... if burning with encrypted firmware it may fail to burn or can t work normally Should decrypt firmware before burning Burning ways as below MCU application layer upgrade Connect unit to PC with USB2 0 to RS232 cable open software UART_ISP_V1 6 exe select correct port set baud rate 115200 type in A1 in PORT select PATH then click UPDATA to finish upgrading ...

Page 26: ...al PT MA HD44M 2 Web Upgrade Connect unit to PC with USB2 0 to RS232 cable open software UART_ISP_V1 6 exe select correct port set baud rate 115200 type in F0 in PORT select PATH click UPDATA to finish upgrading ...

Page 27: ...fee Warranty expiration Factory applied serial number has been altered or removed from the product Damage deterioration or malfunction caused by Normal wear and tear Use of supplies or parts not meeting our specifications No certificate or invoice as the proof of warranty The product model showed on the warranty card does not match with the model of the product for repairing or had been altered Da...

Page 28: ...ce Technical Support Phone 49 5971 800299 0 Fax 49 5971 800299 99 Technical Support Hours 8 30 AM to 5 00 PM Monday thru Thursday 8 30 AM to 4 00 PM Friday Write to PureLink GmbH Von Liebig Straße 10 D 48432 Rheine www purelink de info purelink de ...

Reviews: