User Manual
PT-HDBT-701-TXWP
13
5.3
RS232 Command
Communication protocol:
RS232 Communication Protocol
Baud rate: 9600 Data bit: 8 Stop bit: 1 Parity bit: none
5.3.1
Control Mode Switching
Command
Function
Feedback Example
50779%
Switch to RS232 mode 1
(
Default
)
,
control scaler switcher and the far-end
third-party device.
RS232 Mode 1: RS232
Control Scaler & Remote.
50780%
Switch to RS232 mode 2, control the
scaler switcher from remote.
RS232 Mode 2:RS232 &
Remote Control Scaler
5.3.2
Signal Switching
Command
Function
Feedback Example
50770%
Enable auto-switching
Auto Switching
50771%
Disable auto-switching
Manual Switching
50702%
Switch to HDMI input
Switch to HDMI
50704%
Switch to VGA input
Switch to VGA
5.3.3
VGA Scaling Configuration
The default output resolution for VGA is 1920x1080. Below is a list of the output
resolutions the built-in scaler can output.
Command
Function
Feedback Example
50632%
Check the output resolution
Resolution: xx
50619%
Change the resolution to 1360X768
HD
Resolution: 1360x768
50626%
Change the resolution to 1024X768
XGA
Resolution: 1024x768