background image

6

 

Installation & Operation Manual

Copyright © Puretec Ltd 2019

Z12 / Z18 Assembly

1.  Cut the tube square and push in to 

the tube stop. For metal tube remove 
burrs and chamfer tube end to prevent 

O-Ring seal being damaged.

DISCONNECTION PROCEDURE

               

4.  Push collet against body and slide tube out of fitting.

2.  Fitting grips before it seals. Ensure 

tube is pushed in to tube stop.

HOW TO USE QUICK CONNECT FITTINGS

3.  Tube is secured in position.

Figure 2

Figure 1

1

No.

DESCRIPTION

1

Smart Tee

 

½"M x ½"F x ¼"T

2

White Tubing

3

MultiValve

4

Z1-R

 Filter Cartridge

5

Mounting Bracket

6

Tube, Nut and Olive

7

Tube Insert

8

Faucet Lock Nut and 

Washer

9

Black Plastic Washer

10

Black Rubber Washer

11

Escutcheon Plate

12

Long Reach Faucet or 
High Loop Faucet

2

3

6

9

10

11 

12 

Summary of Contents for Z12

Page 1: ...3497 Licence No WM 74726 Australian Certification Services User Guide Quick Twist Undersink Water Filter System Z12 Z18 For correct operation installation it is essential to observe these instructions JUNE2019 ...

Page 2: ...ct your nearest Puretec stockist Customer Service Helpline 1300 140 140 Australia 0800 130 140 New Zealand Caution Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system What s Inside Operation 3 Cartridge Replacement 3 Installation Requirements and Procedure 3 Cartridge Changeout 4 Use Guidelines 5 Z12 Z18 A...

Page 3: ...tridge ensure you reset the LED reminder light by removing replacing the battery from the rubber seat Please refer to page 6 for a detailed diagram Order Z1 R for a replacement cartridge to suit your Z12 or Z18 system Installation This system comes complete with an installation kit enabling it to be connected to 15 mm male thread This product must be installed in accordance with local plumbing reg...

Page 4: ...e Plastic Washer Lock Washer and Locking Nut onto the thread and tighten ensuring the tap is in the correct position on the bench Then place the Olive in the 1 4 Compression Nut then onto the 1 4 Tube and the Olive Insert into the end of the Tube and attach to the tap thread Z12 Faucet To install faucet place the Escutcheon and Large Rubber Washer onto the base of the tap Insert into the Counter T...

Page 5: ...Guidelines Minimum operating pressure 200 kPa Maximum operating pressure 689 kPa Do not allow exposure to temperatures below 0 C protect from freezing Maximum operating temperature 38 C protect from freezing Nominal flow rate 5 5 Lpm This system must be installed according to local plumbing codes on the cold water line mains only Replacement Cartridge Z1 R This system requires regular replacement ...

Page 6: ...ube out of fitting 2 Fitting grips before it seals Ensure tube is pushed in to tube stop HOW TO USE QUICK CONNECT FITTINGS 3 Tube is secured in position Figure 2 Figure 1 1 No DESCRIPTION 1 Smart Tee M x F x T 2 White Tubing 3 MultiValve 4 Z1 R Filter Cartridge 5 Mounting Bracket 6 Tube Nut and Olive 7 Tube Insert 8 Faucet Lock Nut and Washer 9 Black Plastic Washer 10 Black Rubber Washer 11 Escutc...

Page 7: ...he faucet lever handle see Figure 3 2 Install battery into the battery seat positive side up Note red light flashes twice and then followed by the blue light 3 Reinstall battery seat assembly into the faucet lever Important note Battery must be replaced when changing cartridges 5 Red light flashes indicates your cartridges are due to be changed usage has exceeded 3 000 minutes or 12 months Please ...

Page 8: ...elines 1996 ND Not Detected This appliance meets the domestic water treatment appliance Standards AS NZS3497 for the following water treatment processes Class Treatment type Function Pass I Microbiological Status Bacteriostatic Will stop bacteria increasing but will not remove them unless II a is passed N A II Microbiological Treatment II a Bacteria Removal Will remove or inactivate bacteria N A I...

Page 9: ...is 1 year parts and lanour plus 9 years parts only Excludes cartridges To make a claim under the warranty take the product and proof of purchase to place where you purchased the product and they will lodge a Warranty Request with Puretec Puretec will pay your reasonable direct expenses of claiming under this warranty You may submit details and proof of your expense claim to place of purchase for c...

Page 10: ...the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Warranty New Zealand This warranty is given by Puretec Ltd Reg No 4464398 Level 2 40 Onehunga Mall Auckland 1061 telephone no 0800 130 140 and email at sales puretec co nz This warranty is provided in addition to other rights and remedies you have under law Our goods come...

Page 11: ...11 Quick Twist Undersink Water Filter System with LED Faucet This page was intentionally left blank ...

Page 12: ......

Reviews: