background image

4

 

Installation & Operation Manual

Copyright © Puretec Ltd 2019

Installation Procedure

1.  Select suitable location that is close to the point of filtered water delivery (eg. sink). 

Remember to allow access room for changing filters and a suitable place where water 
spillage will not cause damage. Location should not be in direct sunlight.

2.  Isolate water supply. Uninstall the connections on the cold water line and connect the 

Smart Tee™. Reinstall the previous connection to the tee valve. 

3.  Connect the pressure limiting MultiValve to the Smart Tee™ with a length of White 

Tubing.

4.  Choose the best position for the faucet, taking into consideration height of jugs etc. 

and also the drainage of any spills. Then drill a 012.5 mm hole and install the Faucet 

as in the instructions for your model in step 5.

5.  To install the faucet follow the instructions for your model below. 

Z18 Faucet

: To install the faucet, connect spout to the base of the faucet, ensuring that 

the white circlip is flush with the groove on the spout. Push down on the spout cap 
until it clicks, then tighten by hand. Once connected, place the Escutcheon and O-ring 

supplied onto the base of the tap. Insert into the Counter Top or Sink and place the 

Plastic Washer, Lock Washer and Locking Nut onto the thread and tighten, ensuring 

the tap is in the correct position on the bench. Then place the Olive in the 1/4" 

Compression Nut, then onto the 1/4" Tube and the Olive Insert into the end of the Tube 

and attach to the tap thread.

Z12 Faucet

: To install faucet, place the Escutcheon, and Large Rubber Washer onto the 

base of the tap. Insert into the Counter Top or Sink and place the Plastic Washer, Lock 
Washer and Locking Nut onto the thread and tighten, ensuring the tap is in the correct 
position on the bench. Then place the Olive in the 1/4" Compression Nut, then onto the 

1/4" Tube and the Olive Insert into the end of the Tube and attach to the tap thread.

6.  Reset LED indicator by following instructions on page 6.

7.  Install filter cartridge by positioning it in the desired location, marking the position of 

fixing hole and fixing with bracket screw. Both the Z18 and Z12 Series can be mounted 
horizontally or vertically. Allow room for the connecting tubes. Ensure flow arrow on 
the head is in direction of water flow.

8.  Fit tubing into connectors (for quick-connect fittings instructions see Fig. 2). Allow slack 

in the tubing.

9.  Restore the water supply and check for leaks.

10.  Run the system for at least 5 minutes to remove carbon fines. Water may appear 

milky, but this is normal and is only tiny air bubbles that will clear after a short period.

Installation

Summary of Contents for Z12

Page 1: ...3497 Licence No WM 74726 Australian Certification Services User Guide Quick Twist Undersink Water Filter System Z12 Z18 For correct operation installation it is essential to observe these instructions JUNE2019 ...

Page 2: ...ct your nearest Puretec stockist Customer Service Helpline 1300 140 140 Australia 0800 130 140 New Zealand Caution Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system What s Inside Operation 3 Cartridge Replacement 3 Installation Requirements and Procedure 3 Cartridge Changeout 4 Use Guidelines 5 Z12 Z18 A...

Page 3: ...tridge ensure you reset the LED reminder light by removing replacing the battery from the rubber seat Please refer to page 6 for a detailed diagram Order Z1 R for a replacement cartridge to suit your Z12 or Z18 system Installation This system comes complete with an installation kit enabling it to be connected to 15 mm male thread This product must be installed in accordance with local plumbing reg...

Page 4: ...e Plastic Washer Lock Washer and Locking Nut onto the thread and tighten ensuring the tap is in the correct position on the bench Then place the Olive in the 1 4 Compression Nut then onto the 1 4 Tube and the Olive Insert into the end of the Tube and attach to the tap thread Z12 Faucet To install faucet place the Escutcheon and Large Rubber Washer onto the base of the tap Insert into the Counter T...

Page 5: ...Guidelines Minimum operating pressure 200 kPa Maximum operating pressure 689 kPa Do not allow exposure to temperatures below 0 C protect from freezing Maximum operating temperature 38 C protect from freezing Nominal flow rate 5 5 Lpm This system must be installed according to local plumbing codes on the cold water line mains only Replacement Cartridge Z1 R This system requires regular replacement ...

Page 6: ...ube out of fitting 2 Fitting grips before it seals Ensure tube is pushed in to tube stop HOW TO USE QUICK CONNECT FITTINGS 3 Tube is secured in position Figure 2 Figure 1 1 No DESCRIPTION 1 Smart Tee M x F x T 2 White Tubing 3 MultiValve 4 Z1 R Filter Cartridge 5 Mounting Bracket 6 Tube Nut and Olive 7 Tube Insert 8 Faucet Lock Nut and Washer 9 Black Plastic Washer 10 Black Rubber Washer 11 Escutc...

Page 7: ...he faucet lever handle see Figure 3 2 Install battery into the battery seat positive side up Note red light flashes twice and then followed by the blue light 3 Reinstall battery seat assembly into the faucet lever Important note Battery must be replaced when changing cartridges 5 Red light flashes indicates your cartridges are due to be changed usage has exceeded 3 000 minutes or 12 months Please ...

Page 8: ...elines 1996 ND Not Detected This appliance meets the domestic water treatment appliance Standards AS NZS3497 for the following water treatment processes Class Treatment type Function Pass I Microbiological Status Bacteriostatic Will stop bacteria increasing but will not remove them unless II a is passed N A II Microbiological Treatment II a Bacteria Removal Will remove or inactivate bacteria N A I...

Page 9: ...is 1 year parts and lanour plus 9 years parts only Excludes cartridges To make a claim under the warranty take the product and proof of purchase to place where you purchased the product and they will lodge a Warranty Request with Puretec Puretec will pay your reasonable direct expenses of claiming under this warranty You may submit details and proof of your expense claim to place of purchase for c...

Page 10: ...the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Warranty New Zealand This warranty is given by Puretec Ltd Reg No 4464398 Level 2 40 Onehunga Mall Auckland 1061 telephone no 0800 130 140 and email at sales puretec co nz This warranty is provided in addition to other rights and remedies you have under law Our goods come...