OuTPuTS, diSPlay aNd CONNECTiON PurPOSE 

Edition of 0

9

.12.2020

06

Fig. 8. Diagram of connection to the plasma system PURM-180 MA

TORCH FIRE

Power

supply

source

Control unit

Oscillator

CA

THODE

NOZZLE

Item to be cut

Plasma torch

Overheating

The THC1-DV1 device is installed in close proximity to the plasma source. It minimizes the 

length of high-voltage wires and allows the module energizing from the line to which the 

plasma source is connected.

The THC1-M module is installed in a CNC cabinet and connected to PC via a network switch 

(in case the PLCM controller is used) or directly to the PC network card (if the PLCM is 

unavailable). The data transmission line (DATA CABLE) has no galvanic coupling between 

modules which allows avoiding any interference induction by plasma source to the CNC control 

cabinet. When a PLCM motion controller is absent in the system (PC control movement using 

LPT port), it is necessary to send signals to vacant inputs, since these inputs are galvanically 

isolated by means of an optocoupler, it is necessary to use an external power supply source 

and current-limiting resistors. 

For a device to be found, IP address of your PC and THC1 address must be located in the same 

subnetwork. By default, THC1’s address is 192.168.10.12, which means that the PC’s address 

begins with 192.168.10.xxx, and the last number must not coincide with the PLCM’s or THC1’s 

address. If the device does not appear in the list, see FAQ section. 

It should be noted that for the THC module to be successfully found, the device shall be 

connected to the same network card as the PLCM controller, i.e. if two network cards are 

installed in the computer, and the PLCM controller is connected to one of them, and the THC1 

device  is  connected  to  the  other  one,  then  the  ТНС1  module  will  not  operate.  Both  devices 

shall only be connected to PC via a network switch. The setup procedure of a network card 

for the PLCM controller operation is detailed in the movement controller manual. If THC1 is 

used without a PLCM movement controller, and height is monitored by means of UP and DOWN 

signals via PC’s LPT port, no network switch is necessary. The DHCP switch box is only checked 

if there is a DHCP server or router in the network. That is to say, if PLCM and THC modules are 

connected to PV through a router, then IP addresses are assigned to the devices automatically.

Summary of Contents for THC1-DV1

Page 1: ...02 Set of Delivery 03 Product Features and Specifications 04 Differences between LV and HV inputs of THC1 DV1 module 05 Operating principle 06 Outputs display and connection purpose 07 FAQ 08 Warranty...

Page 2: ...een fully tested with plasma sources manufactured by Hypertherm company which are well proven as reliable and high quality equipment Most of Hypertherm plasma sources are equipped with special connect...

Page 3: ...C1 DV1 module up to 3 mA Measured voltage of plasma cutter arc HV input 0 200 V voltage measurement range 380 V maximal short duration voltage Measured voltage of plasma cutter arc LV input 0 8 V volt...

Page 4: ...4 THC1 Check pumotix com for more information Fig 1 Dimensions of the THC1 DV1 module 03 4 grooves...

Page 5: ...5 Product Features and Specifications Edition of 09 12 2020 Fig 2 Dimensions of the THC1 M module 03 4 grooves...

Page 6: ...isolated from optocoupler The plasma source switches it by means of a relay The CT current transformer input is used if the plasma source is not equipped with a torch firing process monitoring circuit...

Page 7: ...piercing arc voltage is almost always much above the standard value and if control is not blocked this time the torch will begin moving down trying to normalize voltage The delay depends on metal thic...

Page 8: ...it is disabled in CT mode TORCH FIRE green the TORCH FIRE output status It is on if the contacts are closed and it is off if they are opened ERROR red is lit in case of an error LINK green signal of d...

Page 9: ...vider and Arc ok output Position of DIP switches of 1 DV1 module To network switch or PC Twisted pair connector 8 8 NC control console Plasma source Arc voltage Arc transfer Arc transfer Control board...

Page 10: ...10 THC1 Check pumotix com for more information 06 To THC DV1 module To PC network card Fig 7 Connection of modules without a PLCM controller...

Page 11: ...and current limiting resistors For a device to be found IP address of your PC and THC1 address must be located in the same subnetwork By default THC1 s address is 192 168 10 12 which means that the P...

Page 12: ...election menu 1 The Link LED does not blink when Ethernet cable is connected to THC1 Possible causes a damaged cable a malfunctioning network switch a malfunctioning network card connection options ca...

Page 13: ...ot responsible for the quality of their joint operation incorrect selection of component parts In case of any questions you can consult the company s specialists 1 2 Seller does not provide any warran...

Page 14: ...with manufacturer s requirements and if the electrical network and equipment protection devices are unavailable 4 7 The Goods which was re sold by the initial buyer to third party persons 4 8 The Good...

Reviews: