INSTRUCTION MANUAL

SMC4-4-16A16B

Four-axis motion controller

We draw your attention to the fact that there can be some changes in this instruction 

due to the product consistent technical improvement.

Summary of Contents for SMC4-4-16A16B

Page 1: ...160 Leninsky avenue Voronezh Russia 394033 Monday Thursday 8 00 17 00 Friday 8 00 16 00 Break 12 30 13 30 INSTRUCTION MANUAL SMC4 4 16A16B Four axis motion controller We draw your attention to the fac...

Page 2: ...l Control system functions to change or improve upgrade without notice If you have other requirements please contact us OUTLINE Our latest motion controller using high performance 32 bit CPU with an L...

Page 3: ...d 32 bit ARM CPU Liquid crystal display resolution 320 240 Input Output 16 channels opto isolated 10MA inputs 16 channels opto isolated pull down tank 500MA output Users machining program memory can b...

Page 4: ...for the TF card data is extremely strict so the general low end cards cottage card will be excluded and then replace the other genuine card reading For HDSD TF because of the card problem and can not...

Page 5: ...or driver number of subdivisions 360 stepper motor step angle screw thread pitch Example Step angle 1 8 screw pitch 5mm segments 8 pulses equivalent 8 360 1 8 5 320 Maximum speed value the ability to...

Page 6: ...high level Open the file File name appears in the display field the file name format is the standard format 8_3 8 character names 3 suffix When displaying the Chinese have four Chinese name the three...

Page 7: ...is greater than file rows itself At this time point to most caudal of the file Click on from the first line to start and from the selected line to start both will jump to the main interface Open this...

Page 8: ...Coordinate System and Continued points from the beginning There will be some computing time TF card reader speed will affect the current operation speed number of runs in the top left corner indicate...

Page 9: ...he speed of returned to the Mechanical point and the knife point Above Input pin inputs corresponding to 8 controllers Can arbitrarily designated as the current limit input pin Document Management Cli...

Page 10: ...555 63 74 Edit this file You can edit the selected file Return the file selection Re select the file New File Create a new document Delete Files delete the selected file Return to the main interface...

Page 11: ...55 63 74 Edit this line for editing the selected row Corresponding key on the control panel enter the desired G code then press OK button to save and return the old parameters line in the front Repair...

Page 12: ...tcuts as origin Operation Return to origin Z axis rise to Safe altitude XY axis back to the origin Z axis and then passed back to the origin Return to the mechanical origin Z axis retreated mechanical...

Page 13: ...otion controller Edition of 03 08 2016 13 www purelogic ru 8 800 555 63 74 X axis uniaxial cleared Y axis uniaxial cleared Z axis uniaxial cleared A shaft uniaxial cleared All axes cleared Exit Panel...

Page 14: ...ing axis directly run to the specified coordinates Change coordinates corresponding axes directly change toto the number set This operation is not reversible please carefully Operation Spindle control...

Page 15: ...system G Script Parameters G2 G3 tolerance refers to the input G2 G3 after manual calculations or other calculations Because of the accuracy problems so that circular arc center is inconsistent with...

Page 16: ...ction keys rotating advanced function keys you can exceed 33 33 of the system to the maximum speed During standby under Press and hold the stop button black square button press the middle button of se...

Page 17: ...s In the address programmed feed rate F is invalid with G0 move quickly The system will be run by the maximum value of each axis vector synthesis rate To go four cases G0X0Y0Z0 G0X10 G0Y10 G0X0 G0Y0 G...

Page 18: ...the actual running tracks F is the processing speed Painting Quartet Case G0X0Y0Z0 X10F1200 Y10 X0 Y0 G02 G03 Format 1 G02X Y Z R F Radius method 2 G02X Y Z I J K F circle center method Format 1 G03X...

Page 19: ...X Y Z I J K F X Y Z represents Terminal point coordinate F processing speed I represents projection of the arc starting point to circle center distance in the X axis J represents projection of the ar...

Page 20: ...ordinates of the most reasonable When it has some deviation with given center coordinates actually Called super difference If this deviation value is greater than the system given it will prompt an er...

Page 21: ...h a radius of programming By geometric mapping will be two arcs a large arc and a small arc in order not to generate ambiguities provisions R 0 is a small arc R 0 is great arc For full circle because...

Page 22: ...me of interrupt the machining P suffix to be milliseconds a minimum of 500ms P Case delay 1 second G0X0Y0 G1Z 1F1200 G1X20Y20 G04P1000 G1X40Y40 G0Z5 G0X0Y0 G90 default Absolute dimensions G91 Incremen...

Page 23: ...altitude at the beginning represent and Z Terminal point after returned Case coordinates 20 0 20 20 0 20 0 0 four drill holes 5mm in depth the two safety plane a speed of 200 G0X0Y0Z5 G81X20YOR2Z 5F20...

Page 24: ...of 200 G0X0Y0Z5 G82X20YOR2Z 5P1000F200 G82X20Y20R2Z 5P1000F200 G82X0Y20R2Z 5P1000F200 G82X0Y0R2Z 5P1000F200 G0X0Y0Z5 G83 canned cycle drilling instruction Format G83X Y Z R I F X Y represent end coord...

Page 25: ...stor M112 corresponds OUT_12 Output High Level artificially high Facilitate different voltage connect pull up resistor M113 corresponds OUT_13 Output High Level artificially high Facilitate different...

Page 26: ...ine otherwise go on waiting M315 corresponding the input terminal INTPU_15 Judgment if it is low level execute the next line otherwise go on waiting M316 corresponding the input terminal INTPU_16 Judg...

Page 27: ...eturn to point A and wait for the start switch triggered As shown in Figure A position of the origin point B point 500MM C point 1000MM connect the X axis control all circuits An input switch connecte...

Page 28: ...08 2016 28 www purelogic ru 8 800 555 63 74 M301 wait for the start button triggered M47 back to the first line to restart Note The last line of the last to join the carriage return Carriage return or...

Page 29: ...SMC4 4 16A16B Four axis motion controller Edition of 03 08 2016 29 www purelogic ru 8 800 555 63 74...