CNC Ethernet controller
www.purelogic.ru
8 (800) 555 63 74
04. Main connectors and indicators
Fig. 1.
Connectors and indicators connection scheme
Fig. 2/3.
Cable type setup / Speed and duplex mode setup
05
Software installation
1. Turn on the controller and connect it to Ethernet. Link LED must
flash on.
If it does not or blinks and network connection icon appears/disappears
in Windows, automatic type definition went incorrect (this was caused
by special features of some network cards).
In this case it is necessary to set up manually. Click on the [Start] icon-
[Control Panel], [Network and Sharing Center], Local Area Connection
– properties. Then press ‘configure’ (fig. 2). In ‘Advanced tab’ choose
‘Speed and duplex mode’ and set ‘10Mbit per second full duplex’ (fig. 3).
(Parameters and names can slightly differ in different network cards).
2. For device work with MACH3, you need to install plug-in.
Please download zip-file for PLCM controllers from here:
www.purelogic.ru/files/downloads/SOFT/PLCM.zip and run «setup.
exe». Software installation wizard for controller will be started. (fig. 4).
Press ‘Next’. If this is your first installation and you want to have all
necessary drivers installed, choose devices which are planned to apply
on the PC. (fig. 5). If none of the devices is chosen, only plug-in update
for MACH3 will be executed.
• P1 Port represents LTP PC port analog and has identical assignment
and location of contacts:
Outputs 1, 2, 3, 4, 5, 6, 7, 8, 9, 14, 16, 17.
Inputs 10, 11, 12, 13, 15.
• RESET button is for IP-address of controller current value reset to
default value
• Coil short-circuit module protection, wrong stepper motor connection
protection (192.168.10.10).
To do this it is necessary to:
1) Disconnect controller power supply.
2) Press and hold down RESET.
3) Supply power voltage, pressing RESET.
4) Release RESET in 1-2 sec.