background image

Edition from 03.06.2015 

11

PLC330. 

Multichannel stepper motor driver  

www.purelogic.ru

8 (800) 555 63 74

Fig. 5.

 General scheme of CNC control

Brushl

es

s spindl

e

Po

w

er unit 

St

epper mot

or/

Serv

o mot

or 

Fr

equency 

conv

ert

er

Dumper

Some driv

er models

hav

e input dumper

CNC c

ontr

oll

er

St

epper mot

or 

driv

er 

Up t

o 4 driv

er

s c

onnection

PC with ins

tall

ed CNC 

pr

ogr

am MA

CH3

Po

w

er unit 

Limit sensor

Up t

o 5 sensor

connection

27V

27V

12V

Ethernet / USB

LPT-c

abl

e

Connection via 

Relay up t

3 de

vic

es

Contr

ol

LPT-c

abl

e

~220

,

Vacuum  hold do

wn

Cl

eaner

Cooling f

an

Spindl

KRES

S

Coolant  pump

~220

,

~220

,

06. Stepper motor connection

Summary of Contents for PLC330

Page 1: ...06 Stepper motor connection 07 Current and voltage option 08 Commutation timer of a coolant pump 09 PWN convertor voltage 10 Step division option 11 Protection functions setup 12 Common problems 13 Te...

Page 2: ...pcs 03 01 General information Control method Supply voltage Operating current of each stepper motor Step division microstep PWN converter parameters voltage Timer parameters of lubricoolant control M...

Page 3: ...ency 20 kHz for current control in stepper motor coils AUTO SLEEP mode automatically reduces current in stepper motor coils and reduces acoustic noise when in standstill Coil short circuit module prot...

Page 4: ...ack edge DIR signal characteristics are working voltage 3 5V current consumption 0 1 m operation time 1 ms ENABLE signal characteristics are working voltage 3 5V current consumption 0 1 m operation ti...

Page 5: ...pper motor Purelogic R D series PL42 PL57 Purelogic R D stepper motor connection to the driver is performed as it is shown in fig 6 Please note that in case of couple phase interchange PH1 x PH2 x the...

Page 6: ...onverter Dumper Some driver models have input dumper CNC controller Stepper motor driver Up to 4 drivers connection PC with installed CNC program MACH3 Power unit Limit sensor Up to 5 sensors connecti...

Page 7: ...osen 50 70 from the claimed stepper motor coil current Operating current installation is performed according to fig 2 and fig 7 by removable jumpers in XP6 channel 1 XP7 channel 2 XP8 channel 3 XP9 ch...

Page 8: ...rmed according to fig 2 in XP10 The driver allows to divide electronically physical stepper motor step 1 2 8 and 16 Thus positioning accuracy is higher Step division mode is called microstep mode This...

Page 9: ...sibility for glass electric lamps starters and expendable materials as well as 4 1 Damaged product caused by inappropriate transport and store conditions wrong connection operation in abnormal off des...

Page 10: ...onsistent technical improvement You can always download our latest versions at www purelogic ru www purelogic ru Contacts Moscow 7 495 505 63 74 Voronezh 7 473 204 51 56 149 Office 160 Leninsky avenue...

Reviews: