Multichannel stepper motor driver  

www.purelogic.ru

8 (800) 555 63 74

01

02

General information

Delivery  set               

Technical features

PLC330 is a microstepping multichannel driver of stepper motor 

control. The module allows to control 4 machine axes using LPT-port.

The driver has inbuilt coil short-circuit protection, back EMF effect 

protection.

The multichannel driver supports control of frequency converter from 

PWN signal of a controlling program and has inbuilt regulated timer for 

control of a coolant pump. The module has 5 inputs for limit sensors or 

E-STOP button connection.

The device is optimal for control of bipolar and unipolar Purelogic R&D 

stepper motors (PL42/PL57 series). Work with other stepper motors is 

also possible.

• Multichannel driver PLC330 — 1 pcs. 

• LPT-cable — 1 pcs.

• Instruction manual — 1 pcs.

• Board for connecting sensors PLC330 Alarm Mod-A— 1 pcs.

• CD with software — 1 pcs.

03

01. General information

Control method 

Supply voltage

Operating current of each stepper motor 

Step division (microstep) 

PWN converter parameters>voltage 

Timer parameters of lubricoolant 

control 

Max shaft rotation frequency 

Isolation resistance 

Net weight 

STEP Max signal frequency 

Installed relays parameters 

Operating temperature 

Overall dimensions (W x H x D) 

STEP/DIR/ENABLE from LPT port

18...30V (bogey value 27V)

1:1, 1:2, 1:8, 1:16

Uoutp. = 0...9.5V (when changing pulse

Frequency converters control ratio 

Q=0...1)Power 10V from frequency 

convertor 

Operation frequency – 8...60 sec

 Duration – 1...8 sec

30 cycles per second

500 MOhm

0,8 kg

100 kHz

220V/7А

0...50 °С

200 x 49 x 114 mm

0.5А...3.0 А (discrete regulation)

!

Check 

www.purelogic.ru

 for more information.

TURN OFF POWER DEVICE BEFORE MAKING ANY CONNECTIONS AND 

DRIVER OPERATION MODE CHANGINGS.

DO NOT MOUNT THE POWER SWITCH AFTER THE POWER SOURCE 

(ON THE DRIVER POWER LINE).

POWER SWITCH SHOULD BE INSTALLED BEFORE POWER SUPPLY, AT 

~220V SIDE. 

DO NOT CONNECT POWER SUPPLY’S «-» TO GROUND, MASS, 

HOUSING, ETC.

STRICTLY OBSERVE THE POLARITY OF POWER SUPPLY AND CONTROL 

SIGNALS CONNECTIONS.

Summary of Contents for PLC330

Page 1: ...06 Stepper motor connection 07 Current and voltage option 08 Commutation timer of a coolant pump 09 PWN convertor voltage 10 Step division option 11 Protection functions setup 12 Common problems 13 Te...

Page 2: ...pcs 03 01 General information Control method Supply voltage Operating current of each stepper motor Step division microstep PWN converter parameters voltage Timer parameters of lubricoolant control M...

Page 3: ...ency 20 kHz for current control in stepper motor coils AUTO SLEEP mode automatically reduces current in stepper motor coils and reduces acoustic noise when in standstill Coil short circuit module prot...

Page 4: ...ack edge DIR signal characteristics are working voltage 3 5V current consumption 0 1 m operation time 1 ms ENABLE signal characteristics are working voltage 3 5V current consumption 0 1 m operation ti...

Page 5: ...pper motor Purelogic R D series PL42 PL57 Purelogic R D stepper motor connection to the driver is performed as it is shown in fig 6 Please note that in case of couple phase interchange PH1 x PH2 x the...

Page 6: ...onverter Dumper Some driver models have input dumper CNC controller Stepper motor driver Up to 4 drivers connection PC with installed CNC program MACH3 Power unit Limit sensor Up to 5 sensors connecti...

Page 7: ...osen 50 70 from the claimed stepper motor coil current Operating current installation is performed according to fig 2 and fig 7 by removable jumpers in XP6 channel 1 XP7 channel 2 XP8 channel 3 XP9 ch...

Page 8: ...rmed according to fig 2 in XP10 The driver allows to divide electronically physical stepper motor step 1 2 8 and 16 Thus positioning accuracy is higher Step division mode is called microstep mode This...

Page 9: ...sibility for glass electric lamps starters and expendable materials as well as 4 1 Damaged product caused by inappropriate transport and store conditions wrong connection operation in abnormal off des...

Page 10: ...onsistent technical improvement You can always download our latest versions at www purelogic ru www purelogic ru Contacts Moscow 7 495 505 63 74 Voronezh 7 473 204 51 56 149 Office 160 Leninsky avenue...

Reviews: