8
Keypad Navigation
1.
Speed Buttons
- Used to select the run speed desired. The LED above the Speed Buttons will illuminate
when that speed is selected or is currently running. A flashing LED indicates is active on that speeds channel.
2.
Mode select Button
– Choose manual and schedule
3.
Start/Stop Button
- Used to Start and Stop the pump. When the pump is stopped and the LED is not
illuminated, the pump is unable to run from any type of input.
4.
Display Mode LED Indicators
- An illuminated LED indicates the information being displayed on the screen at
any specific point. A flashing LED indicates that the parameter is currently being edited.
5.
Display Button
- Used to toggle between the different available display modes. This button is also used to set the
24-hour clock and screen resolution.
6.
Quick Clean Button
- Used to run a selected speed and duration programmed for Quick Clean. When the LED is
illuminated the Quick Clean schedule is active.
7.
"<" and ">" Arrows
- Choose between a 12 or 24 hour time format.
8.
“+” and “-” Arrows
- Used to make on screen adjustments to the pump settings. The “+” arrow increases
the value of a given setting, while “-” decreases the value of a given setting. Pressing and holding down
either arrow button will increase or decrease the incremental changes faster.
INSTALLATION
Location
NOTICE:
Do not install this pump within an outer enclosure or beneath the skirt of a hot tub or spa unless marked
accordingly.
NOTICE:
Ensure that the pump is mechanically secured to the equipment pad.
Be sure the pump location meets the following requirements:
1. Install the pump as close to the pool or spa as possible. To reduce friction loss and improve efficiency, use short,
direct suction and return piping.
2. Install a minimum of 5 feet (1.52 meters) from the inside wall of the pool and spa. Canadian installations require a
minimum of 9.8 feet (3 meters) from the inside wall of the pool.
3. Install the pump a minimum of 3 feet (.9 meters) from the heater outlet.
4. Do not install the pump more than 10 feet (3.1 meters) above the water level.
5. Install the pump in a well ventilated location protected from excess moisture (i.e. rain gutter downspouts, sprinklers,
etc.).
6. Install the pump with a rear clearance of at least 3 inches (7.6 cm) so that the motor can be removed easily for
maintenance and repair. See
Figure 1
.