19
2. Remount the seal plate to the motor mounting plate.
3. Before installing the rotating part of the seal on the impeller shaft, wet the impeller shaft with soapy water and slide
the seal to the impeller shaft end. Remove the dirt from the contact surface of the seal with a clean cloth.
4. Screw impeller onto the motor shaft (clockwise to tighten).
NOTICE:
Insert a Phillips screwdriver into the hole of the motor fan.
5. Remount the diffuser onto the seal plate.
6. Grease the diffuser quad ring and seal plate O-ring prior to reassembly.
7. Assemble the motor sub-assembly to the strainer pot-pump body. Tighten the bolts until all 4 bolts are in place and
finger tightened.
8. Fill the pump with water.
9. Reinstall the pump lid and plastic clamp; see the next section, ‘Restart Instructions’.
10. Re-prime the system.
Restart Instructions
If Variable Speed Pump is installed below the water level of the pool, close return and suction lines prior to opening hair
and lint pot on pump. Make sure to re-open valves prior to operating.
Priming the Pump
The pump strainer pot must be filled with water before the pump is initially started. Follow these steps to prime the
pump:
1. Remove the pump lid plastic clamp. Remove the pump lid.
2. Fill the pump strainer pot with water.
3. Reassemble the pump cover and plastic clamp onto the strainer pot. The pump is now ready to prime.
4. Open the air release valve on the filter, and stand clear of the filter.
5. Turn on the power to the pump.
6. Press the
Start/Stop
button on the drive keypad. If the pump is currently scheduled to run it will start.
NOTICE:
If the pump is not scheduled to start, press a
Speed
button to begin a manual override that will start the
pump.
7. When water comes out of the air release valve, close the valve. The system should now be free of air and
recirculating water to and from the pool.