PUREGLOW ANNABELLE Installation And User Instructions Manual Download Page 8

FITTING THE DECORATIVE FRAME

Heat Wave, New wave and Media models;

The appliance is supplied with a decorative frame. The frame attaches as a three piece clip-on assembly. If the firebox is to be retained by the
cable method, this is the most convenient stage at which to fit the three piece clip on
frame. Before fitting the frame remove any plastic protective coating. The side pieces
of the clip on assembly should be pushed into position first, followed by the top bar
(shown), which should overlap the sides. 

IMPORTANT NOTE:  Due to the possibility

of sharp edges, care should be taken when handling the three piece frame compo-
nents.  The use of protective gloves is recommended.  Place the firefront into position
in front of the fire and slide the ashpan door into place. Do not use any other firefront
other than the one supplied with this appliance. The firefront shown in these instruc-
tions may differ from the one supplied with the appliance.

Chloe, Juliet, Annabelle, Zara, Carmen, Carmen HIW and Churchill models;

The decorative frames must be fitted later - refer to section 13 of these instructions.

PREPARING THE OPENING

Before installing the fire, check the flue using a smoke pellet. All of the smoke should travel up the flue and exit correctly from the terminal.
If problems are found, DO NOT fit the fire until corrective action is completed.

Protect the decorative hearth whilst pushing the firebox in and out of the opening. Part of the packaging will make an ideal hearth saver pad.

Before running the gas supply into the opening, offer up the firebox to the fireplace
to check the fit is good. Angle the firebox or adjust the spigot outlet as described in
the Fitting the Firebox section. Ensure that it slides in correctly, the sealing face sits flat
and square to the wall or infill panel, and that the base is firm on the floor of the open-
ing as no leaks are permissible here. At this stage it is essential to ensure that the spig-
ot outlet of the fire is not restricted in any way. Remove the firebox and take any nec-
essary measurements before making good and preparing for final installation.

Apply the self adhesive sealing strips to the back of the fireframe to give a continuous
seal.

CABLE FIXING. For fixing of the fire by the cable method, see the relevant section.
The cable fixing locations should be marked on the back of the opening and the holes
drilled. Fit the wallplugs and eyebolts supplied to these holes. 

SCREW FIXING. For fixing by screw, mark and drill the fireframe or base, and the rel-
evant points in the opening or on the wall. Wallplugs will again be required. Pre-punched holes are not provided for this purpose to allow you
to choose the optimum positions.

GAS SUPPLY. Following preparation for the fixing method, the concealed gas supply, where required, can now be put into place. Refer to the
gas supply section for suggested pipe routes. The ends of the sleeving in which the gas pipe is run should be sealed. The ends of the 8mm
supply pipe should be temporarily sealed to prevent the ingress of debris during fixing.

GAS SUPPLY ROUTING

When the opening is ready for installation of the fire, the gas supply can be routed as shown in the diagram below.  IMPORTANT - Wherever
a concealed connection is made a rubber grommet must be used to seal the firebox.

8.1

9.0

10.0

6

© 2009 Pure Glow Limited 

Inlet restrictor elbow

Grommets

Fireplace opening

Firebox

Summary of Contents for ANNABELLE

Page 1: ...C 11 09 Country s of destination GB IE FULL DEPTH RADIANT GAS FIRE FOR USE WITH CHLOE JULIET NEW WAVE HEAT WAVE MEDIA CHURCHILL ANNABELLE ZARA CARMEN CARMEN HIW Pure Glow Limited Stourvale Road Lye St...

Page 2: ...he appliance is designed for installation on to a non combustible hearth of at least 300mm depth This appliance is factory set for operation on the gas type and at the pres sure stated on the applianc...

Page 3: ...ce with the Gas Safety Installation and Use Regulations 1998 the relevant British Standards for Installation Codes of Practice and in accordance with the Manufacturers Instructions The installation sh...

Page 4: ...is installed into and the one venting the gases into the air A suitable terminal may be fitted such as class GC1 as regulations allow This appliance has been tested for use in a pre cast block flue co...

Page 5: ...e back of the appliance must have a 50mm mini mum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet must form a smooth path into the...

Page 6: ...BRICATED FLUE BOXES This appliance can be fitted into a number of proprietary flue boxes provided that the minimum dimensions given in the diagram below are complied with Constructional Note The frame...

Page 7: ...rebox on it s back Lay the tapered panel onto the rear face of the firebox The side panels should be fitted by inserting their front edges into the pre fitted retaining brackets on the front face of t...

Page 8: ...is good Angle the firebox or adjust the spigot outlet as described in the Fitting the Firebox section Ensure that it slides in correctly the sealing face sits flat and square to the wall or infill pan...

Page 9: ...should be posi tioned as close to the correct layout as possible Before finally fitting cables ensure the self adhesive sealing strips are in position on the back of the appliance frame The fireframe...

Page 10: ...control knob in slightly and continue turning anti clockwise to the high position The main burner should light after a few seconds To decrease the setting to LOW turn the control knob clockwise to the...

Page 11: ...highest setting and any communicating doors open Finally repeat with all doors open DO NOT allow the fire to be used until the test is satisfactorily passed BRIEFING THE CUSTOMER All instructions mus...

Page 12: ...ing leg and lift assembly clear The injector pipe can now be checked for debris Remove the nut retaining the injector elbow Blow through the elbow to remove any debris The valve is not field serviceab...

Page 13: ...me and then cuts off Excessive room draught or flue pull rectify Loose or faulty thermocouple rectify ODS system in operation Firebox grommet seal not fitted rectify Lint in pilot aeration hole clean...

Page 14: ...his fire the coals or pebbles must be of the correct type and laid out in accordance with the relevant section of these instructions Failure to do so could create a hazard or lead to soot ing Before t...

Page 15: ...ge test must be taken into consideration when assessing ventilation requirements this will have been car ried out by your registered installer For Republic of Ireland ventilation may be required see I...

Page 16: ...he second row of coals in order to complete the third row The coals may be orien tated as desired to achieve a realistic effect Keep the spacing between the coals even and uniform The two coals at the...

Page 17: ...orts The fuel bed layout is now complete The fire is designed to operate correctly with the pebbles supplied when assembled according to the instructions Never add to the six teen pebbles or change th...

Page 18: ...ld be the problem and removal of the draught should resolve this The fire can then be re lit in accordance with the previous section A grommet seal may also be missing from the firebox causing abnorma...

Page 19: ......

Reviews: