PUREGAS, LLC
P200W2 Series Dehydrator User’s Guide
Page 77 of 82
P012213 – Rev. F
12. Appendix
12.1 Set Point Limits and Defaults
12.1.1
System Operations
Description
Minimum
Value
Maximum
Value
Default
Value
Unit of
Measurement
High Pressure Limit –
Turn Compressor OFF
1.4 55.2 10.3 KPa
Low Pressure Limit –
Turn Compressor ON
0.7 54.5 2.0 KPa
12.1.2
Alarm Set Points
Description
Minimum
Value
Maximum
Value
Default
Value
Unit of
Measurement
Shutdown
High Pressure Alarm
1.4
55.2
20.7
KPa
Low
Pressure
Alarm 0.7 54.5 1.0 KPa
High Cabinet
Temperature Alarm
32 60 49 Deg
C
YES
Low Cabinet
Temperature Alarm
1 6 1
Deg
C
YES
High
Humidity
Alarm
6 18 7 % YES
High Duty Cycle Alarm
0
99
50
%
12.1.3
Network Setup
Description Format Example
IP Address
Numeric (xxx.xxx.xxx.xxx)
192.168.001.100
Subnet Mask
Numeric (xxx.xxx.xxx.xxx)
255.255.255.000
Gateway Address
Numeric (xxx.xxx.xxx.xxx)
192.168.001.001
SNMP Trap Server
Address
Numeric (xxx.xxx.xxx.xxx)
192.168.001.255
Current Date/Time
Numeric (mm/dd/yy hh:mm)
01/27/11 10:02
Device ID
Alphanumeric (10 digits)
ABCD 12345
Keyword
Numeric (6 digits)
123456 (default)