background image

LDENTIFICATION

ELECTRICAL SUPPLY

PRINCIPLE OF OPERATION

For future reference, write down the model, serial number, and date of purchase for your 
dehumidifier.
This is extremely helpful if you need to seek assistance in the future. The data label on the 
side of your unit has the key characteristics of your specific machine.

The Sentinel Series Dehumidifier utilizes its integral humidistat to monitor the conditioned 
space.When the relative humidity goes above the selected set point, the dehumidifier will 
energize. Air is drawn across an evaporator coil, which is cooler than the dew point of air. 
This means moisture will condense out of the air. The air is then reheated through the 
condenser coil and distributed back into the room.

For aditional questions concerming your dehumildifer, the following options 
are available:

   Contact your installing contractor
   E-mail; [email protected]

MODEL NUMBER:

SERIAL NUMBER:

DATE OF PURCHASE:

POWER SUPPLY:

 

OUTLET REQUIREMENT:

 

CIRCUIT PROTECTOR:

 

240 Volts AC may cause serious injury from electric shock.

WARNING

TO REDUCE RISK OF INJURY: 

1. Disconnect electrical power before servicing
2. Only plug unit into grounded electrical circuit
3. Do not use an extension cord.
4. Do not use a plug adapter

WARRANTY REGISTRATION

SAFETY NOTES

Congratulations on purchasing a new Sentinel Dehumidifier. Your new dehumidifier
comes with an extensive warranty plan. To register, simply fill out and return the
warranty form provided in the dehumidfier box.
Be sure to note your dehumidifier serial number as you will need it for registration.

The Sentinel Series Dehumidifier must always be connected using a grounded electrical
connection (as required for all electrical appliances). If non-grounded wiring is used, all 
liability reverts to owner and the warranty is voided.

Sentinel Dehumidifiers should only be maintained and repaired by a qualified 
technician.

Sentinel Dehumidifiers are only intended for operation when oriented with the unit stting
on its feet and level. Operating the unit in any other orientation could allow water to 
flood electrical components.

If there is a chance that water flooded the dehumidifier, it should be opened and allowed
to dry thoroughly before reconnecting to electrical power and restarting.

To ensure proper operation, neither the inlet nor discharge should be positioned against 
a wall. The inlet requires a minimum of 12”clearance and the discharge requires a 
minimum of 36" clearance.

The best option for proper diffusion of air throughout the room is to have the discharge
blowing away from a wall and the inlet pulling air in parallel to a wall.

Always unplug dehumidifier before moving.

Do not insert your fingers or any object into the inlet or discharge.

AlI work on the dehumidifier should be done with the unit “off” and unplugged.

Do not use water to clean the exterior of the machine. To clean unit, unplug from power,
then use a damp cloth to wipe exterior.

Do not stand on the machine or use it as a device to hang clothes.

PureAiro 

DSC 55S

PureAiro DSC 55S

115 V, 60 Hz AC, Single Phase

3-Prong,GFI

15 Amp

02

03

INSTALLATION

The area to be controlled should be sealed with a vapor barrier. If unit is installed in a 
crawlspace,all vents should be sealed.

Do not install your dehumidifier in a corrosive environment. Some liquid vapor
barriers dry via“solvent evaporation". Always make sure that barrier is 
completely dry and area is throughly ventilated before installing dehumidifier.

WARNING

STEP #1: PLACE DEHUMIDIFIER ON A LEVEL SURFACE.

Do not place directly on vapor barrier. For example, use blocks, or pavers to create a level 
surface.

If the unit is handled in such a manner that the compressor did not remain in the upright 
postion,it is necessary to place on a level surface and wait a minimum of 2 hours before 
turning the unit“on”

Summary of Contents for DSC 55S

Page 1: ...ion Compatible with Remote Control Notice sold separately Coated coils with the stainless side plate Engineered for low temperature operation and the air ow issues like the crawl space or attic Multip...

Page 2: ...uctural integrity Increased humidity levels indoors can cause the growth of mold and mildew and an increase in dust mites These are known allergens that cause respiratory problems and asthma This is w...

Page 3: ...Dehumidi ers should only be maintained and repaired by a quali ed technician Sentinel Dehumidi ers are only intended for operation when oriented with the unit stting on its feet and level Operating t...

Page 4: ...is powered on it shows the humidity of the space 2 While setting the desired humidity level the screen wil show the set humidity After a brief delay the display will revert to current humidity level W...

Page 5: ...ves you multiple options for remotely controlling your unit in addition to monitoring the conditions surrounding the dehumidifer One application for the remote control is to install the dehumidi er in...

Page 6: ...to pull out and down on base of adapter This will lift hooks out of cover holes INSTALLING SUPPLY DUCT ADAPTER To install adapter line up with holes on the side of unit and push up from base of adapte...

Page 7: ...according to instructions listed in manual Air Filter is Clogged Low Air Flow Clear the blockage from inlet or outlet Machine is Not Level Loud Noise Check to ensure that wire is connected at both en...

Page 8: ...refrigerant CUSTOMER RESPONSIBILITIES In order to take advantage of the warranty service the customer must do the following Customer must provide normal care and maintenance including but not limited...

Reviews: