MAINTENANCE
Always unplug the unit before doing any maintenance.
WARNING
CLEANING THE MACHINE BODY
COIL MAINTENANCE
Use a soft, damp cloth to clean the exterior of unit. Do not use any soap or solvents.
Unplug the unit.
For PreFilter:
ELECTRICAL ACCESS
1.
2.
3.
**
For more detailed instructions, visit www.PureAiro.com**
Once per year, clean the coils with an approved coil cleaner. The coil cleaner should be a
self-rinsing, foaming, cleaner, such as WEB® Coil Cleaner.
CLEANING THE FILTER
a. Remove prefilter from inlet of machine.
b. Vacuum or wash with warm water (no soap).
For MERV-10/HEPA/Carbon Filters:
a. Replace as necessary- we recommend
checking the filters at least 1x/year
Unscrew the 13 screws on the side panel.
Remove the 2 screws on the control board cover.
PUMP MAINTENANCE
Your PureAiro DSC 120ES is equipped with an integral condensate pump designed to
pump water from the dehumidifier out to the desired drain.
The pump requires routine maintenance that is not covered by the warranty.
Preventative maintenance is necessary to prevent issues from dirt and slime that may
accumulate in the drain system. This includes the drain pan, hose to the condensate
pump,pump reservoir, pump head assembly, and discharge tubing.
1
2
3
4
Remove the 9 screws on the side panel and set
panel aside.
Remove the screw holding the pump in place.
Undo the 3 pump electrical quick connects and 1 drain quick connect.
Insert a flat head screwdriver into the notch on the side of the pump. This will allow you
to gently lift the pump off its reservoir (the reservoir remains attached to the unit).
REMOVING THE PUMP
BASIC PUMP CLEANING
Complete about once per year, depending on environment
Remove filter(s) from inlet of unit to access drain tray. Press the drain button to drain
the reservoir.
Disconnect power to the dehumidifier.
Mix a 453.6g solution of bleach (30 ml 443.6 ml water) OR vinegar (118.3 ml
white v 354.9 ml water).
Pour the cleaning solution into the drain tray at the base of the coils.
If any cleaning solution gets on the coils, flush with water.
Allow solution to soak for 15 minutes.
Reconnect the dehumidifier to power.
Fill the reservoir with water (473.2-946.4 ml) and flush/cycle the pump at least 2x.
If the drain line is still filled with debris, repeat process. If drain line still does not
appear clean, move on to Advanced Cleaning.
1
2
3
4
5
6
7
8
ADVANCED PUMP CLEANING
Complete as needed
Press the drain button to drain the water from the reservoir (a wet-dry vacuum or towels
can be used to remove any remaining water).
Unplug the dehumidifier and remove the cover so you have access to the pump.
Remove the pump head from the reservoir by unscrewing the screw.
Wipe reservoir clean with a paper towel.
Reassemble pump.
1
2
3
4