 PUREAIR AIR PURIFICATION SYSTEM

PHOTOCATALYTIC OXIDATION (PCO) TECHNOLOGY

CAUTION

LAMPS CONTAIN MERCURY.

Ingestion of or contact with mercury or mercury va­
por is hazardous to your health.

Take care when handling lamps. If lamp breaks,
avoid contact with mercury.

NOTICE

Hg -- Lamps contain mercury.

Manage in accord with disposal laws.

Refer to www.lamprecycle.org or call
1-800-9LENNOX.

Proper Clean-Up of Broken UVA Lamps

If a lamp is broken, it must be disposed of properly.

Wear protective gloves, eye wear and mask.

Sweep broken glass and debris into a plastic bag. Seal
the bag and dispose of according to instructions given
by local waste management office.

Do not use a vacuum cleaner. Do not incinerate.

Troubleshooting Flow Chart

See figure 8 (Page 8) for the troubleshooting flow chart.

Annual Maintenance Kits

The Annual Maintenance Kits include one MERV 16 filter,
one PureAir Insert and two lamps. Kit part numbers are
as follows:

Part

Description

Part Number

PCO14-23

PCO16-28

PCO20-28

Annual

Maintenance Kit

X8797

X8796

X8795

Replacement Parts

Replacement parts are available through Lennox, see
figure 1 (Page 2) for parts arrangement. Part description
and numbers are as follows:

Part Description

Part Number

PCO14-23

PCO16-28

PCO20-28

Cabinet

X8917

X8916

X8915

Access Door

X8920

X8919

X8918

UVA Lamp

X8794

X8794

X8794

Reflector

X8926

X8925

X8924

Lamp Securing Clip

X8927

X8927

X8927

PureAir™ Insert

X8793

X8792

X8791

MERV 16 Filter

X8790

X8789

X8788

Power Cord (120VAC)

49M48

49M48

49M48

Power Cord (230VAC)

91X44

91X44

91X44

Control Box Assem­
bly, includes * items

X8923

X8922

X8921

*Electrical Socket

75X77

75X77

75X77

*Lamp Socket

X8799

X8799

X8799

*Ballast

X8798

X8798

X8798

*Surge Protector

X8928

X8928

X8928

Summary of Contents for PCO14-23

Page 1: ...n system It may take up to 48 hours after initial system start up to reduce the airborne chemicals that have built up in a home over a long period of time For peak performance unit should be installed in homes with TVOC levels that are less than 1000 micro gram cubic meter Home source removal and ventilation may be required to lower TVOCs to this level NOTICE This system is NOT intended to be used...

Page 2: ...e would be restricted A metal transition should be used The transi tion must be planned for each job Reduction should not be more than 4 inches per linear foot approximately 20 angular degrees Note At sharp turns install turn ing vanes before the PCO Upflow Side Installation Upflow Side installation with PCO access panel pointed upward and lamps suspended vertically NOT RECOMMENDED Contact the Tec...

Page 3: ...Resistance Cabinet and Filter Capacity Tons Flow Rate CFM Pressure Drop in w g PCO14 23 PCO16 28 PCO20 28 2 800 0 12 0 11 0 09 2 5 1000 0 17 0 15 0 12 3 1200 0 22 0 20 0 16 3 5 1400 0 28 0 25 0 19 4 1600 0 30 0 23 4 5 1800 0 28 5 2000 0 32 Not recommended Excessive system pressure drop can damage HVAC system and reduce performance Installation Select a Location The PCO must be installed in the ret...

Page 4: ...these components remain clean until the cabinet installation is completed Reflector Lamp Socket Lamp Lamp Securing Clip Slide lamp pins into lamp socket and pivot lamp inward onto lamp securing clip Pins Figure 5 Lamp Installation Top View CAUTION Lamps contain mercury Ingestion of or contact with mercury or mercury va por is hazardous to your health Take care when handling lamps If lamp is broken...

Page 5: ...ceptacle on the PCO cabinet and the other end into a power receptacle 5 Look through the view port in the access door to check that the lamps are illuminated NOTE On initial start up the lamps may not reach full illumination for several minutes CAUTION Ultraviolet UVA radiation risk Prolonged exposure may cause skin or eye damage Avoid prolonged weeks exposure to skin or eyes NOTICE MERV 16 filter...

Page 6: ...ment MERV 16 filter UVA lamps and PureAir Insert which are provided in the Replacement Kit Remove all protective wrapping materials 2 Unplug the power cord and remove the PCO access door 3 Slide out the control box assembly and remove the existing MERV 16 filter 4 Check air flow direction of the MERV 16 filter and insert replacement filter into the PCO cabinet 5 Remove the existing PureAir Insert ...

Page 7: ...for the troubleshooting flow chart Annual Maintenance Kits The Annual Maintenance Kits include one MERV 16 filter one PureAir Insert and two lamps Kit part numbers are as follows Part Description Part Number PCO14 23 PCO16 28 PCO20 28 Annual Maintenance Kit X8797 X8796 X8795 Replacement Parts Replacement parts are available through Lennox see figure 1 Page 2 for parts arrangement Part description ...

Page 8: ...otector and ballast Replace any burned out or damaged components and plug unit in Is there power to PCO Are lamps lit Are lamps lit Gently pull on lamp to make sure the lamps are in place Did lamps light YES STEP INPUT OUTPUT WIRE TERM COLOR NORMAL READING SERVICE ACTION See wiring diagram Figure 7 Page 5 SPM 1 INPUT BLACK 105 Replace input power connection or socket if less than 105 VAC WHITE 2 R...

Reviews: