page 8
Mega-Classic Owners Manual
Installation
CAUTION
:
:
:
:
: The Mega Classic weighs approximately 75 lbs. Follow these instructions
to prevent injury.
1.
Open the carton from the bottom by cutting along the dotted line with a utility
knife.
2.
Carefully slide the carton up so the distiller is in the upright position when the
carton is removed.
3.
Remove and identify all parts kits as listed on page 4.
Connecting the Incoming Water Line
Notes and Cautions:
Note
: The use of softened water for the raw water supply is recommended to
minimize scale build-up in the boiling tank and automatic drain valve.
Note
: The Mega-Classic comes standard with a saddle tapping valve. In some
areas a saddle tapping valve may not be permitted. In such instances, contact
your authorized Pure Water, Inc. Distributor for other water line connection
options.
CAUTION
: DO NOT use a hot water line for your supply line.
CAUTION
: DO NOT turn the saddle tapping valve handle before or during
installation. Be sure the piercing lance does not protrude beyond the rubber
gasket. Failure to do this may result in damage to the piercing needle.
To hook-up the Incoming Water Line:
1.
Locate the parts kit bag identified “Raw
Water Hook-Up Kit”.
2.
Turn the household water supply OFF.
3a. For installation on
copper pipes
:
a.
Assemble the saddle tapping valve on
the cold water pipe so the outlet is in a
convenient direction. See figure 1.
b.
Tighten the screws evenly. The brackets
should be parallel. Tighten firmly, but
do not overtighten.
Caution: The Mega-
Classic is heavy.
Please use caution
during installation.
Caution: Never use the
hot water line for your
incoming water.
Figure 1
Note: The use of
softened water is
recommended to
minimize scale
build-up in the
boiling tank.