F i n a l I n s p e c t i o n
• Turn the water to the system on, plug the system in and let the reservoir fill. RO systems will fill
in
one to two hours. Filtration (M) system will fill in 5 to10 minutes.
• Activate dispense sensors to verify flow from hot and cold tanks.
• Drain cold water into container using the dispense nozzle. Activate touchless dispense sensor
until water flow ceases or refer to programming section regarding system flush mode.
• Located on the rear of the system is a hot tank drain. Holding a bucket under the drain,
remove
drain cap and allow the system to drain until water flow stops. Replace drain
cap.
• Repeat steps 1 through 4.
• Allow system to fill.
• Turn hot switch located on back of unit to “ON” position.
• Allow unit to sit for 4 hours to reach optimal operating temperature.
Verify the following:
•
There are no leaks or loose components.
•
The hot water is over 160°F.
•
The cold water is below 50°F.
•
Confirm acceptable product water flow
•
PW90CT-R systems- Average tank fill for RO systems is 45 hours.
•
PW90CT-M systems- Average tank fill for filtration systems is 5 minutes.
•
The system exterior is clean and all components are in place.
OTHER ITEMS
1. Once a system has been flushed it should remain plugged in and water
dispensed occasionally.
2. Always drain the system before moving it. It is not necessary to drain the Hot
Tank completely through the rear Hot Tank drain. Leaving water in the Hot Tank
will allow turning on the Hot Tank immediately after installation of the system.
3. Never lay the system on its side.