3.5 Pro & Commercial System
Assembly
18
UPPER WASH VESSEL SETUP
●
Set up the platform and allow for 29” minimum platform height (from the floor to the platform standing area). This is required
for the downspout to clear the lower filtration vessels. The false bottom goes into the upper wash vessel.
●
Gaskets must be used at every port connection in order to form a seal between the ports. The sanitary clamp holds the port
assembly together, hand tighten only.
●
The drain and skim ports need to be oriented to drain into the lower filtration vessels.
●
Attach 90 degree elbows & ball valves to the skim and drain ports.
●
The sight glass goes on the larger 2” port.
●
Attach the temperature gauge directly underneath the skim port.
●
The rear port is used for filling the vessel with one of the two pumps.
○
First attach the check valve on your fill port. The flow arrow should point toward the vessel.
○
Attach the elbow, and Wye fitting next. The 2 ports on the Wye fitting also get check valves to prevent cross
contamination from one water supply to another. The flow arrows should point toward the vessel.
○
Attach the two hoses to the splitter fitting. One will come from your supply water pump. The other will come from your
reclaim / waste water pump.
○
The reclaim water pump is also used to recirculate water from the filtration vessels back to the upper wash vessel
during operation. This pump is also used to transfer the waste water to a drain or collection tank after the batch is
completed.
●
Be sure any unused ports on the wash vessel are capped and ball valves closed before filling.
LOWER FILTRATION VESSEL SETUP
●
Place the lower vessels on the assembled triangular dollies and position under the drain and skim ports. These filtration
vessels will contain the stack of micron filtration bags during operation.
●
Attach a single ball valve, 90 degree elbow and hose to the drain port of each vessel. Those two hoses are attached to a Tee
fitting. A single hose will go from the Tee fitting to the inlet side of the pump used for waste water & recirculation.
●
The outlet side of this pump gets a Wye fitting and 2 ball valves. One hose goes to waste water, the other goes back to the
upper wash vessel Wye fitting.
●
Be sure any unused ports on the filtration vessels are capped and ball valves closed before filling.
*REMEMBER TO CLEAN YOUR EQUIPMENT BEFORE USE*
Note:
Gaskets must be used at every port
connection in order to form a seal between
the ports. The sanitary clamp holds the port
assembly together, hand tighten only.
Summary of Contents for Bruteless
Page 1: ...Bruteless Hash Washing Vessels and Systems User Manual Rev1...
Page 16: ...3 2 Base System Assembly Cont Bruteless Base System Assembly Diagram 15...
Page 18: ...17 3 4 Commercial System Assembly...
Page 20: ...3 6 Pro System Assembly Bruteless Pro System Assembly Diagram 19...
Page 21: ...Bruteless Commercial System Assembly Diagram 3 7 Commercial System Assembly 20...