Model: PIM-E   

Powerline Interface Module  

ELKM1 Data Bus 

Installation Guide and  

Owner’s Manual 

 

 

The Inventors Of: 

 

 

©2010 Powerline Control Systems, Inc.  All Rights Reserved.

 

19215 Parthenia St.  Suite D 

Northridge, CA 91324 

P: 818.701.9831  

[email protected]

  

www.pcslighting.com

 

https://pcswebstore.com

  

 

 

FUNCTION 

The  PIM-E  is a special Powerline 
Interface  Module  containing  a 
built-in M1XSP Serial Port chip.  
This all-in-one device makes it 
easy to permanently connect the 
ELK  M1 Control to  a UPB 

network.  Simply locate a 
convenient  unused AC Power 
Outlet, connect a cable from the 
M1 data bus to the four (4) terminals on the  PIM-E, and 
perform an M1 data bus enrollment.  The  long distance 
capability of the M1 data bus makes it possible to locate the 
PIM-E  virtually anywhere, without a lot of complex or ugly 
cabling or connections.  UPB utilizes the AC wiring  circuit  for 
transmission,  without  new or additional wiring,  and  without 
radio frequency signals.        

Note: The PIM-E will not work 

with UPStart configuration software.

 

IMPORTANT SAFETY INSTRUCTIONS

  

When using electrical products, basic safety precautions should 
always be followed, including the following: 

 
1.

 

READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 

2.

 

Keep away from water.  If the product is exposed to water 
or other liquid, turn off the circuit breaker and unplug the 

product immediately. 

3.

 

Never use products that have been dropped or damaged. 

4.

 

Do not use this product outdoors. 

5.

 

Do not use this product for other than its intended 
purpose. 

6.

 

To avoid any risk of fire, burns, personal injury or electric 
shock, install this product out of the reach of small 
children. 

7.

 

Do not cover product with any material when in use. 

8.

 

This product uses grounded plugs and sockets to reduce risk 
of electric shock.  These plugs and sockets fit only one way.  
If they do not fit, consult an electrician. 

 

SAVE THESE INSTRUCTIONS. 

INSTALLATION

 

This device is designed for indoor use only.   Follow these steps 
to connect the PIM-E module to the ELK M1 Control. 

1.

 

Connect a four-conductor cable from the M1 RS485 Data 
bus to the four (4) terminals on the bottom of the PIM-E.  
Observe polarity and color code from diagram.  

2.

 

Plug PIM-E into any grounded wall outlet.  The Status LED 
should start blinking and then stay solid blue. 

     

Connecting to M1 Control using a single homerun cable. 

 

M1 application using two (2) data bus homerun cables 

 

Connecting devices on an ELK-M1DBH Data Bus Hub 

An ELK-M1DBH Data Bus Hub (Optional) Can be used to connect data bus 

devices using Cat5/6 cables. Devices appear to be in daisy chain because 1 

wire pair returns the data bus back where it’s used to feed next device OR 

gets terminated by special RJ45 Plug. Only 6 of the 8 total conductors are 
used.  

 

                   

 

 