background image

 

Model: PIM-E   

Powerline Interface Module  

ELKM1 Data Bus 

Installation Guide and  

Owner’s Manual 

 

 

The Inventors Of: 

 

 

©2010 Powerline Control Systems, Inc.  All Rights Reserved.

 

19215 Parthenia St.  Suite D 

Northridge, CA 91324 

P: 818.701.9831  

[email protected]

  

www.pcslighting.com

 

https://pcswebstore.com

  

 

 

CONFIGURATION

 

1.

 

From  M1  Keypad  Programming (or ElkRP Software) 
perform a Data Bus Enrollment.  Upon successful 
enrollment, the PIM-E should display as a “M1XSP” located 
at data bus Address #7.  

This address is factory set and 

cannot be changed.

  If another M1XSP is installed on the 

M1 and assigned Address #7 please change its address and 
re-enroll. 

2.

 

From ElkRP Software, select the “Globals” Menu and then 
tab “G29-G42 (Special)”.  On this tab locate and program 
the UPB Lighting Network Addr (1-255) to match the 
address chosen for the UPB network. 

3.

 

Program the format for each ElkM1 Lighting device as 
“Serial Expander”.  

UPStart Configuration  

PCS’s free UPStart  software  V  5.1  Build  45  ,a Powerline 
Interface Module PIM-R (9-pin serial) or a PIM-U (USB serial), 
are used for computer setup and programming of a UPB 
network. These PIM’s can be carried with the technician’s PC 
and used on future jobs. The PIM-E can only be used with the 
ElkM1 and is not for PC setup or programming. The UPStart 
User’s Guide (available on the PulseWorx web site: 
www.PulseWorx.com) explains how to configure your system 
using the UPStart. 
 
Follow the steps described below to configure PIM-E: 

SETUP Mode 

When configuring a UPB system, it will be necessary to place 
the PIM-E in SETUP mode.  To do this, press the Program Button 

5

  times rapidly.  The Status LED will continuously blink Blue 

when the device is in SETUP mode.  To exit SETUP mode, press 
the Program Button 

once

  or wait five minutes for it to time 

out. 

Step 1: Add the PIM-E to the UPB Network 

Select the 

Device

Add

  menu item in the UPStart Setup 

Software. Once UPStart finds your PIM-E it will

 produce a screen 

allowing you to assign it a name and choose what room it is located in.

  

Step 2: Start PIM-E Configuration 

Double-click the PIM-E icon to begin configuration.  Select the 

Advanced 

tab to set the receive sensitivity. 

 
The PIM-E has an adjustment for UPB receive sensitivity.  The 
factory default for this setting is “High”.  If the PIM-E is used in 
severe powerline noise, you may find that it operates better in 
the “Low” receive sensitivity setting. 
 
To adjust the receive sensitivity press the “Advanced” button on 
the UPB Interface Setup dialog.  Select the desired receive 
sensitivity and press the “OK” button. 

 

Step 3: Program the PIM-E 

Once you have specified the desired configuration, press the 
Program Device button to program the information into the PIM-E. 

Factory Default 

In addition to Setup Mode the push-button on the front of the 
case can be used to restore the device to factory default settings. 
To set the  factory defaults first press the pushbutton 

5

  times 

rapidly.  The Status LED will blink blue.  Next, press the pushbutton 

10

  times.  The Status LED will blink red.  Finally, press the 

pushbutton 

2

 times.  The Status LED will stop blinking.  The device 

is now restored to its factory default state.  

Network ID: 

255 

Unit ID: 

45 

Network Password: 

1234 

OPERATION 

Once installed and configured your PIM-E will  operate without 
further user intervention.  All programmed data is protected by 
nonvolatile memory and can only be changed or deleted by 
reprogramming, regardless of power outage durations. 

Status LED Indications

 

The PIM-E contains two bi-color (blue/red) Status LEDS that give a 
visual indication of what  UPB  information  is currently on the 
powerline and communication with the M1 Bus. 

UPB STATUS 

Blue: 

No UPB Signal 

Magenta:  Received a UPB Message 
Red: 

Transmitted a UPB Message 

 

M1BUS STATUS 

Slow Blink : 

Normal Communication with M1 

Fast Flicker: 

Command being sent or received to M1 

No Blink/Off     Communication lost with M1 

LIMITED WARRANTY 

Seller warrants this product, if used in accordance with all applicable instructions, to be free 
from original defects in materials and workmanship for a period of five years from the date of 
purchase.  Refer to the warranty information on the PulseWorx website (www.PulseWorx.com) 
for exact details. 

These products may be covered under one or more of the following U.S. patents: 6,734,784; 
6,784,790; 7,265,654; 7,688,183. U.S. and foreign patents may be pending. PCS, PulseWorx, UPB 
are registered trademarks and PulseWorxRF are trademarks of  Powerline Control Systems, Inc.    
Made and printed in the U.S.A. 

Reviews: