Models: KPCW6 & KPCD6
Keypad Controllers
Installation Guide and
Owner’s Manual
The Inventors Of:
FUNCTION
The 6-Button Keypad Controller (KPCx6) is a high quality
home automation controller that is capable of transmitting
UPB (Universal Powerline Bus) digital commands over the
existing power wiring to remotely turn on, off, and dim other
UPB load control devices. No additional wiring is required
and no radio frequency signals are used for communication.
Wall-Mount and Desktop Styles
The KPCx6 is available in two different styles: wall-mount and
desktop. The KPCW6 is the wall-mount version and can be
mounted in any wall box that contains both line and neutral
wires. The KPCD6 comes in an elegant desktop enclosure
that can be freely located near any wall outlet that exists
throughout the home.
Engraved Pushbuttons
The KPCx6 has six backlit pushbuttons engraved with the
designations of:
ON
,
OFF
,
A
,
B
,
C
, and
D
. A Custom Engraved
Membrane kit (model CEM6) is available enabling you to
tailor each button for its particular use. Consult your dealer
or our website (www.PulseWorx.com) for CEM6 ordering
information.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical products, basic safety precautions
should always be followed, including the following:
1.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
2.
Keep away from water. If the product comes in contact
with water or other liquid, turn off the circuit breaker and
unplug the product immediately.
3.
Never use products that have been dropped or
damaged.
4.
Do not use this product outdoors.
5.
Do not use this product for other than its intended
purpose.
6.
Do not cover this product with any material when in use.
7.
This product uses polarized plugs and sockets (one blade is
larger than the other) to reduce the risk of electric shock.
These plugs and sockets fit only one way. If they do not fit,
consult an electrician.
8.
SAVE THESE INSTRUCTIONS.
INSTALLATION
The Keypad Controllers are designed for indoor use. Simply plug
the KPCD6 into any 120V power outlet. To install the KPCW6
module in a wall box follow these instructions:
1.
Before installing the KPCW6 into a wall box, ensure that
power to the wall box has been disconnected by removing
the fuse or turning the circuit breaker off. Installing
products while the power is on may expose you to
dangerous voltage and may damage the product.
2.
Remove any existing wall plate and device from the wall
box.
3.
Use wire nuts to securely connect the KPCW6’s white wire
to the “Neutral” wire and the KPCW6’s black wire to the
“Line” wire (see illustration below).
4.
Fit the KPCW into the wall box and secure with mounting
screws. Install the wall plate.
5.
Restore power at the circuit breaker.
ON
OFF
Wall
Box
Line
(Black)
Neutral
(White)
19201 Parthenia St. Suite J
Northridge, CA 91324
(Phone) 818-701-9831 (Fax) 818-701-1506