The charger will operate with default values for the essential user settings when it is powered
on for the first time. The screen displays the following system settings in sequence and the
user can change the parameter value on each screen.
When you want to change the parameter value, press START/ENTER to make it blink, then
change the value with INC or DEC. The value will be stored by pressing START/ENTER once.
ITEM
SELECTION
DESCRIPTION
Safety Timer
ON 120Min
OFF/ON
(1-720MIN)
When you start a charge process, the inte-
gral safety timer automatically starts running
at the same time. This is programmed to
prevent overcharge the battery if it proves to
be faulty, or if the termination circuit cannot
detect the battery full. The value for the safe-
ty timer should be generous enough to allow
a full charge of the battery.
ON
5000mAh
Capacity
Cut-Off
OFF/ON
(100-50000MAH)
This program sets the maximum charge
capacity that will be supplied to the battery
during charge. If the delta peak voltage is not
detected nor the safety timer expired by any
reason, this feature will automatically stop
the process at the selected capacity value.
Temp Cut-Off
ON 50°C 122°F
OFF/ON
(20°C/68°F -
80°C/176°F)
The battery’s internal chemical reaction
will cause the temperature of the battery to
rise. If the temperature limit is reached, the
process will be terminated.
Temperature Unit
Celsius
Celsius
Fahrenheit
You can choose the temperature displayed
by Celsius or Fahrenheit as you like.
Rest Time
CHG>DCHG 10Min
1-60min
Rest time allows the battery to cool down
between charging/discharging cycle.